− 109 −
2
When FOOT PEDAL ADJUSTMENT button
B
s pressed,
the foot pedal adjustment screen is displayed and the number of
steps in terms of the depressing depth of the foot pedal is set.
3
Pedal sensor voltage value in the present pedal depressing state
is displayed in the range of 0 to 99 in the volume bar indication
C
.
First, press PEDAL DEPRESSED TO REVERSE STEP INPUT
button
D
with the foot pedal depressed to the reverse step.
Voltage value of this time is inputted to
E
. Next, press FREE
INPUT button
F
with the foot pedal free. Voltage value of this
tme s nputted to
G
. Using the same procedure, perform setting
of first to seventh steps of the foot pedal, and input the voltage
value of the respective pedal positions to buttons
E
,
G
and
H
.
Set the voltage value so as to increase as the number of steps of the foot pedal increases.
In addition, when directly pressing button
E
,
G
or
H
, the ten key input screen is displayed, and it
is possible to directly input numerals.
B
H
C
G
E
F
D