− 117 −
Error code
Description of error
How to recover
E496
condensation at sewing end length over
When condensation pitch X number of stitches exceeds 15.0 mm
Possible to
re-start after
reset.
E497
Back tack at sewing end length over
When back tack pitch X number of stitches exceeds 6.0 mm
Possible to
re-start after
reset.
E498
condensation at sewing start length over
When condensation pitch X number of stitches exceeds 15.0 mm
Possible to
re-start after
reset.
E499
Back tack at sewing end length over
When back tack pitch X number of stitches exceeds 6.0 mm
Possible to
re-start after
reset.
E702
CPU runaway detection
When program abnormality has occurred in CPU
Turn OFF the
power.
E703
Panel is connected to the sewing machine which is not
supposed (Machine type error)
When the machne type between panel and sewng machne s
different in the initial communication
Possible to
re-start after
reset.
E704
Inconsistency of system version
When system software version is inconsistent in the initial
communcaton
Turn OFF the
power.
E730
Main shaft motor is defective or lacking for phases.
When encoder of sewing machine motor is abnormal
Turn OFF the
power.
E731
Main motor hole sensor is defective or position sensor is
defective.
When hole sensor of sewing machine motor or position sensor is
defective
Turn OFF the
power.
E733
reverse rotation of main shaft motor
When the sewng machne motor rotates n the reverse drecton
Turn OFF the
power.
E802
Power momentary cut detection
When nput power s momentarly cut
Turn OFF the
power.