− 29 −
(2) Sewing screen (Independent sewing mode)
*
It is possible to customize display/non-display of the respective buttons.
-13. CUSTOMIZING THE DATA INPUT SCREEN” p.75
I
C
F
E
G
H
A
B
D
Symbol
Name of button
Description
A
INTERLINING SUPPLY button
When this button is pressed, interlining is supplied.
*
This is displayed when “With” of
, automatic interlining supplying device is set
with the optional setting.
B
TYPE OF WELT CHANGE-OVER button
Type of welt change-over screen is displayed and change-over of type of welt and adjustment
of parallelism of the binder can be performed.
C
CLAMP UP PROHIBITION AT SEWING END
button
When this button is held pressed, the clamp is returned in the lowered state at sewing end.
It is convenient to use this button at the time of adjustment of marking light or trial sewing.
D
DIRECT PATTERN LIST button
Direct pattern list screen is displayed and selection of the sewing data can be performed.
E
COUNTER CHANGE-OVER button
When this button is pressed, the display of sewing counter and number of pcs. counter is
changed over.
*
This button is displayed only when both sewing counter and number of pcs. counter are
ON.
F
COUNTER VALUE CHANGE button
This button changes the counter value which is displayed at present.
G
BOBBIN THREAD (RIGHT) REMAINING
AMOUNT VALUE
This button detects reflecting light from bobbin and informs that bobbin thread remaining
amount is running out. When one stitching completes, the counter value is subtracted, and
the count-up screen is displayed when “0” is reached.
*
This button is displayed only when the reflecting light from bobbin is detected.
H
BOBBIN THREAD (LEFT) REMAINING
AMOUNT VALUE
This button detects reflecting light from bobbin and informs that bobbin thread remaining
amount is running out. When one stitching completes, the counter value is subtracted and the
count-up screen is displayed when “0” is reached.
*
This button is displayed only when the reflecting light from bobbin is detected.
I
MARKING LIGHT SETTING button
Marking light setting screen is displayed, and changeover of marking light irradiation position
and setting of change of marking light set value
,
and
are performed.