− 54 −
. . . Item that is not displayed due to other setting state
No.
Item
Setting range
/
Edit unit
Initial value
Second stitch pitch of condensation sewing at sewing start
Second stitch pitch of condensation sewing at sewing start is set.
*
It is possible to set only when
is set to selection of condensa-
ton.
*
It is possible to set only when
is set to selection of condensa-
ton/back tack detaled settng.
0.1 to 1.5
/
0.1mm
1.0mm
third stitch pitch of condensation sewing at sewing start
Third stitch pitch of condensation sewing at sewing start is set.
*
It is possible to set only when
is set to selection of condensa-
ton.
*
It is possible to set only when
is set to selection of condensa-
ton/back tack detaled settng.
0.1 to 1.5
/
0.1mm
1.0mm
Number of back tack stitches at sewing start
Number of back tack stitches at sewing start is set.
*
It is possible to set only when
is se to selection of back tack.
1 to 12
/
1 sttch
3 sttches
Back tack pitch at sewing start
Back tack sewng ptch at sewng start s set.
*
It is possible to set only when
is se to selection of back tack.
0.5 to 3.0
/
0.1mm
2.0mm
Back tack tie stitch pitch at sewing start
Back tack te sttch at sewng start s set.
*
It is possible to set only when
is se to selection of back tack.
–2.0 to 2.0
/
0.1mm
–1.5mm
First stitch pitch of return of back tack at sewing start
First stitch pitch of return section of back tack sewing at sewing start is set.
*
It is possible to set only when
is se to selection of back tack.
*
It is possible to set only when
is set to selection of condensa-
ton/back tack detaled settng.
0.1 to 3.0
/
0.1mm
2.0mm
Second stitch pitch of return of back tack at sewing start
Second stitch pitch of return section of back tack sewing at sewing start is set.
*
It is possible to set only when
is se to selection of back tack.
*
It is possible to set only when
is set to selection of condensa-
ton/back tack detaled settng.
0.1 to 3.0
/
0.1mm
2.0mm