− 58 −
No.
Item
Setting range
/
Edit unit
Initial value
Flap length
Length of flap is set.
It is possible to set only when
automatic interlining supplying
device is selected to motion and
sewing mode changeover is
selected to flap sewing.
*
This setting is set to determine the interlining feeding length of auto
-
matic interlining supplying device. Sewing length is determined by the
detection of flap sensor.
37.0 to
220.0
/
0.1mm
150.0mm
Sewing speed under the high-speed mode
Number of revolutions at lockstitch section is set.
*
It is possible to set only when
sewing speed setting selection is
set to pattern data selection.
1000 to
3000
/
100sti/min
2500sti/min
Sewing speed under the low-speed mode
Number of revolutions at condensation and back tack sewing sections is
set.
*
It is limited by
sewing speed under the high-speed mode.
*
It is possible to set only when
sewing speed setting selection is
set to the selection of pattern data.
*
In case of back tack sewing, the upper limit of number of revolutions of
the actual low speed is limited to 1,500 sti/min.
1000 to
2500
/
100sti/min
1500sti/min
. . . Item that is not displayed due to other setting state