− 64 −
2
Level 2
Memory swtch data (level 1) are the moton data that the sewng machne has n common and the data
that operate on all sewing patterns in common. The data are for the maintenance personnel and possible
to edt by pressng the mode swtch as long as 6 seconds.
No.
Item
Setting range
/
Edit unit
Initial value
Marking light mounting
Mounting/Non-mounting of marking light is selected. When “Non
mountng” s selected, markng lght does not work.
- - -
Non mountng
Mountng
Sewing position selection
Mode that surely ends sewing at rear reference position, mode that
surely starts sewing from front reference position or the conventional
motion mode that changes sewing position according to the setting of
s selected.
*
Front reference position : 80 mm from needle
Rear reference position : 300 mm from needle
For the long and wde type, t s 330 mm.
However, when
s set, t s 380 mm.
- - -
Conventonal mo
-
ton mode
Sewng poston
fixed mode (Rear
reference)
Sewng poston
fixed mode (Front
reference)
Setting of solenoid valve for corner knife separate drive
Mounting/non mounting of solenoid valve for corner knife separate
drve s set.
- - -
Non mountng
Mountng
Pedal operation mode change-over
Mode to be used for foot pedal is set.
- - -
7-step pedal mode
1-shot pedal mode
Excess rate of center knife cutting
Excess rate in terms of the speed of revolution of center knife can be
set.
300 to
500
/
1%
350%