– 34 –
Once the cloth gude has been adjusted to 5mm poston, check to be sure that the numerc value on the
main digital display shown on the amplifier is 3500 or more when no material is placed under the sensor unit,
and that the numerc value on the man dgtal dsplay s 500 or less when the materal s placed under the
sensor unt.
If the aforementioned requirements are not satisfied, the machine can malfunction. It is therefore
necessary to adjust the sensitivity of the amplifier.
Amplifier
1
for the start sensor s located on the
control box.
Amplifier
2
for the curve sensor s located at the
rghtmost poston on the top face of the cloth plate.
1
2
6-8. Adjusting the sensors
Main digital display (indication in red)
The amount of light received is
displayed.
Sub digital display (indication in green)
The threshold is displayed.
SET/RUN changeover switch
SET/RUN mode changeover
Function keys
Setting and
operation of the
functions
UP
DOWN
MODE
The switch for the start sensor is
assigned to D.
The switch for the curve sensor is
assigned to L.