– 17 –
1
2
When
switch
1
is pressed for one second or
longer under normal mode, USB data writing func-
tion is enabled. When
switch
2
is pressed for
one second or longer, network data transmission
function is enabled.
“Wait” blinks on the 7-segment indication block dur-
ing data output.
(4) Outputting measurement data
In transmission data indication under normal mode, it is possible to indicate 30 different data
depending on the No. switch input combination and check the IP address in a similar fashion to
other ID data indication.
The sewing machine ID can be checked by No. 29 (switches
+
) for transmission data,
and the IP address by No. 30 (switches
+
).
e.g. For IP address 192.168.1.106,
1st block
After 1.5 seconds
2nd block
After 1.5 seconds
3rd block
After 3 seconds
4th block
After 1.5 seconds
Clock indication
(5) How to change over the shift
1
2
3
Shift number can be changed over by turning the
power on with
switch
3
held pressed.
Select the desired shift number by means of
switch
1
or
switch
2
.
0 :
No shift number
1-3 : Select the shift number set in 1A-1.
Refer to HELP for 1A-1 for details of the shift.