– 107 –
17. Error E905
17-1) Heat sink temperature of the
1-A) Failing in cooling.
Check whether electric box cooling is effective.
Thermal error in SDC board
SDC board has exceeded 85
°
C.
Look for clogging around air suction holes and check
LED3 on SDC board: Flashing
the fan, etc.
13 times
1-B) The SDC board is out of order.
Replace the SDC board.
18. Error E907
18-1)Irregular motor rotations
1-A) There are irregularities in the
Check the mechanism and look for the section that
X origin retrieval error
mechanism, such as
is particularly overloaded or whether screws are
overloading, etc.
loose.
1-B) Motor leads are broken.
Disconnect CN42 (white) of the MAIN board and
The motor is out of order.
check the motor resistance. [See the Motor/
Solenoid Circuit Diagram.] Replace the motor.
1-C) The MAIN board is out of order.
Replace the MAIN board.
18-2)No sensor signal entry
2-A) The sensor is out of order or
Check whether the sensor lamp is turned ON/OFF
Use of Test Mode CP-1 or CP-2
broken.
when a metallic plate is moved closer to or separated
from the sensor plane. In the case of no lamp ON/
OFF, the sensor is broken or the connector block is
disconnected.
2-B) The INT board connector is
Check the connection of CN62 (red) of the INT board.
disconnected.
2-C) Sensor mounting position is
Check and correct the sensor mounting position.
inadequate.
19. Error E908
19-1) Irregular motor rotations
1-A) There are irregularities in the
Check the mechanism and look for the section that
Y origin retrieval error
mechanism, such as
is particularly overloaded or whether screws are
overloading, etc.
loose.
1-B) Motor leads are broken.
Disconnect CN43 (blue) of the MAIN board and check
The motor is out of order.
the motor resistance. [See the Motor / Solenoid
Circuit Diagram.] Replace the motor.
1-C) The MAIN board is out of order.
Replace the MAIN board.
19-2)No sensor signal entry
2-A) The sensor is out of order or
Check whether the sensor lamp is turned ON/OFF
Use of Test Mode CP-1 or CP-2
broken.
when a metallic plate is moved closer to or separated
from the sensor plane. In the case of no lamp ON/
OFF, the sensor is broken or the connector block is
disconnected.
2-B) The INT board connector is
Check the connection of CN63 (yellow) of the INT
disconnected.
board.
2-C) Sensor mounting position is
Check and correct the sensor mounting position.
inadequate.
Trouble
Cause (1)
Cause (2)
Check and corrective measures
Summary of Contents for LK-1900A
Page 20: ... 16 10 Hook adjustment Standard Adjustment 0mm 0mm 7 5mm 0 05 0 1mm For DPX5 For DPX17 ...
Page 90: ... 86 Grease Grease Grease Grease Grease 8 Needle thread clamp mechanism area ...
Page 91: ... 87 Grease Grease A Grease Grease Grease Grease 9 LK 1901A relations ...
Page 92: ... 88 10 LK 1903A relations Grease Grease ...
Page 114: ... 111 12 Circuit diagrams 1 Block diagram A ...
Page 115: ... 112 2 Power supply circuit diagram A ...
Page 116: ... 113 3 Power supply circuit diagram B ...
Page 117: ... 114 4 Power supply circuit diagram C ...
Page 118: ... 115 5 Servo motor circuit diagram ...
Page 119: ... 116 6 Sensor pedal VR circuit diagram ...
Page 120: ... 117 7 MAIN PANEL board circuit diagram ...
Page 121: ... 118 8 Motor solenoid circuit diagram Thread trimmer Lifting the work clamp foot motor ...