– 54 –
Indication
Level
Functions
Setting range
Remarks
S
Standard pedal, clamp switch position 50~200
70
When the setting value is increased, the
amount of pedal tread becomes larger.
S
Standard pedal, 2-step stroke switch
50~200
120
When the setting value is increased, the
position
amount of pedal tread becomes larger.
S
Standard pedal, start switch position
50~200
185
When the setting value is increased, the
amount of pedal tread becomes larger.
U
Optional pedal 1 operated
0: OFF when trodden again
0
1: OFF when released
U
Optional pedal 2 operated
0: OFF when trodden again
0
1: OFF when released
U
Height of work clamp foot at the
50~90
70
Height is lowered when the set value
time of 2-step stroke
is increased.
S
Clamp lowering speed during pedal
100~4000pps
4000
operation (Setting possible in the
unit of 10pps)
S
Clamp rising speed during pedal
100~4000pps
1500
Too much rise in the setting
operation (Setting possible in the
level may result in malfunction.
unit of 10pps)
S
Thread trimmer clamp rising spped 100~4000pps
3000
Too much rise in the setting
at the end of sewing (Setting
level may result in malfunction.
possible in the unit of 10pps)
U
Pattern’s enlargement / reduction
0: Origin
0
The enlargement / reduction
reference point
1: Sewing start point
point in the pattern data is
effective only for 0 setting.
U
It is possible to stop sewing machine
0: Disabled
0
operation with panel’s reset key.
1: Panel’s reset key
2: External switch
U
Buzzer sound can be prohibited.
0: No buzzer sound
2
1: Panel’s operation sound
2: Panel’s operation sound +
Error sound
U
No. of stitches for needle thread
1 ~ 7 stitches
2
clamp release
U
Clamping timing of needle
–10~0
0
Delayed in negative direction
thread clamp
(~–1:84
°
, 0:80
°
)
in the unit of 4
°
.
U
Needle thread clamp control
0: Normal
0
Set at 1 for LK1903A.
disabled
1: Disabled
U
Selection of feed operation timing. –8~16
12
Delayed in negative direction in the
Set in negative direction when the
(~11:64
°
, 12:60
°
, 13:56
°
~)
unit of 4
°
. If set at extreme negative,
tightness of stitches is adverse.
there is danger of needle breakage.
Significant when handling heavy
materials.
U
State of work clamp foot after
0: Work clamp foot goes up
1
LK-1903A/BR-35 to be set at 0
completion of sewing can be
after moving at the sewing
selected
start.
1: Work clamp foot goes up
immediately after the end
of sewing
2: Work clamp foot goes up by
pedal operation after moving
attne sewing start.
LK1903A
S
Sewing is possible only with the
0: Normal
0
start switch, without raising the work
1: Work clamp foot rise
clamp foot.
disabled.
U
Each time sewing is finished, origin 0: No origin retrieval
0
retrieval is possible. (Except for the 1: Origin retrieval enabled
cycle sewing)
U
Origin retrieval setting is possible
0: No origin retrieval
0
after cycle sewing.
1: Origin retrieval after the end
of one pattern.
2: Origin retrieval after the end
of one cycle.
State when
delivered
Summary of Contents for LK-1900A
Page 20: ... 16 10 Hook adjustment Standard Adjustment 0mm 0mm 7 5mm 0 05 0 1mm For DPX5 For DPX17 ...
Page 90: ... 86 Grease Grease Grease Grease Grease 8 Needle thread clamp mechanism area ...
Page 91: ... 87 Grease Grease A Grease Grease Grease Grease 9 LK 1901A relations ...
Page 92: ... 88 10 LK 1903A relations Grease Grease ...
Page 114: ... 111 12 Circuit diagrams 1 Block diagram A ...
Page 115: ... 112 2 Power supply circuit diagram A ...
Page 116: ... 113 3 Power supply circuit diagram B ...
Page 117: ... 114 4 Power supply circuit diagram C ...
Page 118: ... 115 5 Servo motor circuit diagram ...
Page 119: ... 116 6 Sensor pedal VR circuit diagram ...
Page 120: ... 117 7 MAIN PANEL board circuit diagram ...
Page 121: ... 118 8 Motor solenoid circuit diagram Thread trimmer Lifting the work clamp foot motor ...