28
−
Adjustment Procedures
Results of Improper Adjustment
Mechanical origin is as shown in the figure on the left side.
In the lateral direction, the center of needle hole, the center of X
feed support shaft and the center of Y feed support shaft become
a straight line.
Fit the point by adjusting 2) Y origin sensor and 3) X origin sensor.
™
M a x i m u m a r e a c a n n o t b e
secured.
™
Distortion of stitching shape will
occur.
*
1) Select “Test mode No. 2 Origin retrieval”. (For LK-1910/20
only)
*
2) Simultaneously pressing
and
in the operation
panel, turn ON the power. (For LK-1930 only)
*
3) Press
in the operation panel. (For LK-1930 only)
4) Every time depressing the pedal, the origin is retrieved. Loosen
sensor slit setscrew
1
and shift the position of Y sensor slit
2
to set the feed plate to the position of origin.
(Caution) After the adjustment, make sure that Y sensor slit
2
does not interfere with Y sensor
3
.
* : Selection of model