51
−
Level
S
S
U
U
U
U
U
S
S
U
U
U
U
S
U
U
S
Function
Needle thread breakage detection function is provided
or not. (Detected at 8 stitches at sewing start and 3
stitches in midway)
Selection of whether to execute intermediate presser
control (Intermediate presser action delay is omitted
and the cycle-time is shortened by setting "without
intermediate presser control" when initial setting of LK-
1920. Approximately 0.1 sec)
Selection of upper/lower sweeping of wiper
Selection of air pressure detection
Origin correction when using presser of AMS-206
(Automatic shift to Y = -12 mm immediately after origin
retrieval)
Selection of basting mode
Sewing data of pattern is read to “jump feed” and point
of inflection to “sewing” respectively, and operation is
performed.
Selection of output of optional disk floating solenoid
Do not change setting
Selection of automatic preparation action when turning
the power ON (Mode that pattern reading is executed
and the condition is put in sewing when turning the
power ON.)
Making use of inversion command of pattern data,
select whether to use inversion presser or thread
tension controller No. 3 drive.
Selection of presser lifting timing after completion of
sewing
Selection of action of return to sewing start point
If it is made effective, the machine traces sewing pattern
and returns to sewing start point (only when inversion
presser is used.).
Selection of output of needle cooler
Selection of thermal protect detection
(Normally use “0”.)
Selection of control of thread trimming command of
pattern data (Even when it is ineffective, it is effective
when stopping in midway or the like.)
Selection of control of thread trimming device
(In any case, thread trimming is not possible.)
Selection of model at the time of delivery
(Initial setting)
Setting range
0 : No
1 : Yes
0 : No
1: Yes
0 : Wiper sweeps above
intermediate presser.
1 : Wiper sweeps below
intermediate presser.
0 : No
1 : Yes
0 : No
1 : Yes
0 : Normal
1 : Basting
0 : No
1 : Yes
0 :
1 :
2 :
0 : No
1 : Yes
0 : Connection with inversion
clamp presser
1 : Connection with thread
tension controller No. 3
0 : Thread trimming presser
lifting after return to origin
1 : Presser lifting immediately
after thread trimming
0 : Normal
1 : Trace
0 : No
1 : Yes
0 : Yes
1 : No
0 : Yes
1 : No
0 : Yes
1 : No
10 : LK-1910 / S
11 : LK-1910 / A
20 : LK-1920 / S
21 : LK-1920 / A
(/ S : Magnet type)
(/ A : Pneumatic type)
State at the time of delivery
1
LK-1910 : 0
LK-1920 : 1
0
LK-1920 only
Solenoid type : 0
Pneumatic type : 1
1
0
1
2
0
1
0
0
0
0
0
0
Depending on the
specifications
When changing, all
memory switches are
initialized to default
values.
No.