– 18 –
Standard Adjustment
3) Timing between the Needle and the Hook
Align the center of the needle with the blade
point of the hook.
Requirements:
• The hand-wheel pointer should point
Graduation [L] on the hand-wheel.
• The stitch dial should be set to [0] on the
scale.
• The adjustment should be performed after
the needle bar has been adjusted to the
correct height.
Graduation [L] on the hand-wheel
Pointer on the
hand-wheel
Hand-wheel
Reverse feed lever
(1.4
±
0.2mm)
(2.0
±
0.2mm)
Blade point of the hook
Center of the needle
Lower shaft
Lower shaft coupling
L