– 19 –
Adjustment Procedure
Results of Improper Adjustment
1. Set the stitch dial to [0] on the scale.
2. Loosen the set screw
of the set collar
of the hook driving shaft.
3. Align the hand-wheel pointer with Graduation [L].
4. Turn the hook in the normal direction until the blade point of the hook
is aligned with the center of the needle.
5. Fasten the set screw
.
(Caution)
Adjust the needle entry in the needle slot of the feed
dog with reference to the feeding direction prior to the
adjustment of “Timing between the needle and the
hook”.
o Loose stitches, stitch skipping or
thread breakage may result.
3’ Refer to [3-(1) Types and Names
of Graduations on the Hand-
wheel].
5’ Hold the hook by hand at the cor-
rect position to maintain accurate
needle-to-hook timing and fasten
the set screw
.