JUMAR REG-03 

Mini

CONNECTION DESCRIPTION

Terminal

No.

Designation

Input/

Output

Description

1

2

F2

F1

input

input

Main fuse connector

3
4

L

N

input
input

Power supply connector

5

6

L

N

output

output

Igniter connector

7
8

L

N

output
output

Feeder connector

9

10

L

N

output

output

Fan connector

11
12

x
L

x

output

Central heating pump connector

13

14

STB

STB

input

input

STB fuse connector (bimetal 95

°

C)

15
16

CH
CH

input
input

Central heating sensor connector

17

18

FIRE (-)

FIRE (+)

input

input

Fire sensor connector (opto element)

19
20

FEED
FEED

input
input

Burner feeder sensor connector (bimetal 75

°

C - 90

°

C)

21

22

TH

TH

input

input

Room thermostat/External control connector

(if not use, put a jumper)

Fire sensor (polarity):

CAUTION!!

Bad connection of the sensor causes the weak response of the sensor to the flame/fire.

- 9 -

FIRE (+)

FIRE (-)

Input 17

Input 18

Summary of Contents for REG-03 Mini

Page 1: ...F THE PELLET S BURNER REG 03 Mini INSTRUCTION OF INSTALLING AND THE MAINTENANCE 1 MENU OK REG 03 Mini MODE INFO JUMAR REG 03 Mini FAN CO CH PUMP STB STB IN BUILD C ROOM THERMOSTAT ALARMS FAN SPEED REG...

Page 2: ...JUMAR REG 03 Mini 2...

Page 3: ...ON DIAGRAM 8 OPERATION CONTROLLER 11 BUTTON S DESCRIPTION 11 THE DRIVER S HANDLING 12 MEASURE PANEL DESCRIPTION 13 ALARMS 14 WORKING MODES 15 TEMPERATURE SETTING 17 MENU STRUCTURE 18 SETTINGS TABLES 1...

Page 4: ...to the maintenance and the safe using of the device Before installing please read the instruction carefully and get to know the functioning of the driver Any questions occur contact with the JUMAR co...

Page 5: ...others devices of high power without appropriate net filters Avoid putting signal wires in a direct contiguity and in parallel to energetic and powering wires Avoid closeness of remotely controlled d...

Page 6: ...iac 230V 2A 0 8A Fan triac 230V 2A 0 8A Pump relay 230V 2A 0 8A Protection Temperature build in STB 80 C 400 C Electric external Fuse 4A Inputs Room thermostat Open contact Fire sensor Opto element He...

Page 7: ...a particular temperature in the room To controller added timer functions now user can set heating time THE PRICIPLE OF WORKING The device s work is based on providing fuel via steering the feeder app...

Page 8: ...or to network it is necessary to check all the connections carefully One has to take particular note of not placing 230V power supply cables instead of the sensor Improper connection may permanently d...

Page 9: ...l heating pump connector 13 14 STB STB input input STB fuse connector bimetal 95 C 15 16 CH CH input input Central heating sensor connector 17 18 FIRE FIRE input input Fire sensor connector opto eleme...

Page 10: ...CH CH Sensor Central heating water sensor CH 3 FEED Burner Sensor The sensor protects the burner against excessive temperature growth Bimetal sensor has to selected according to the burner 4 FIRE Fir...

Page 11: ...nu or change a parameter s value New value can be accepted by this button Screen change Increase value of temperature Goes up in the settings menu sub menu or increase a value of parameter Decrease va...

Page 12: ...ntroller show measurement panel The following figure shows an example of the appearance of LCD screens By using the button you can switch to the display visualizing the action of particular burner s e...

Page 13: ...2 Icon indicating the fan operation 3 If fan working icon will be animated Icon indicating the igniter operation 4 Is displayed alternately with the icon of the feeder Icon indicating the feeder oper...

Page 14: ...es the burner to stop and switch into damping mode The burner s operation is blocked The display will show the following message STB alarm has to be reseted manually after decreasing the temperature b...

Page 15: ...left ashes The cleaning function also as a blow down before ignition WORK Heating the boiler up to the set temperature Showing the actual power of the burner PAUSE Sustaining the set temperature if th...

Page 16: ...ates functions linked to the ignition of the pellet if the particular burner s function requires it The driver carries out three trials of ignition of the pellet The lack of flame may be caused by the...

Page 17: ...e set value Heating water temperature CH boiler hysteresis activates the burner function If there is no flame in the burner it will be ignited again In the picture below illustrates how change a value...

Page 18: ...particular group s parameters In order to make changes of the parameters by pressing button To change the values buttons ought to be pressed Press so as to save the new settings In the picture below...

Page 19: ...in contin 4 FEEDER FILLING SET TIMER PARAMETER NO PARAMETER NAME UNIT SETTING RANGE DEFAULT VALUE 1 TIMERS SETTINGS HOURS 0 23 0 SET CLOCK PARAMETER NO PARAMETER NAME UNIT SETTING RANGE DEFAULT VALUE...

Page 20: ...ARM 6 SENSOR ALARM 7 AVERAGE CONSUMPTION 8 TOTAL CONSUMPTION Only in V2 0 firmware CAUTION The manufacturer s settings are only the suggestions All values depend on the kind of solid fuel installation...

Page 21: ...e in the last group and would like to switch lower then the first group will be selected again Similarly when you are in the first group and would like to switch to a higher one you will switch to the...

Page 22: ...the boiler or ignite the pellets again Setting the hysteresis more than 5 C is reasonable only when heating the central heating buffer 2 CH PUMP TEMPERATURE The threshold temperature of starting the...

Page 23: ...rner in the function of maintain the temperature of the heating water is higher than the pre set The chosen power of the burner is a visual value depending on the quality of the applied pellet The pow...

Page 24: ...hould be reduced to minimum temperature C 24H C WEEKLY functions EXAMPLES OF TIMER ADJUSTMENTS IN 24H MODE AS WELL AS IN WEEKLY MODE TIMER 24H The figure below shows exemplary setting of burner operat...

Page 25: ...is possible to change the hour interval 1 2 into the burner switched off The burner will provide heating between 1 00 AM and 2 00 AM TIMER WEEKLY The figure below shows exemplary setting of burner op...

Page 26: ...tart Pressing the MENU button again will cause switching to the time of program stop Pressing the MENU button again will cause switching to burner operation mode The UP DOWN button changes the mode to...

Page 27: ...eter s description No Parameter name Description 1 CURRENT DAY Setting of current day of week 2 CURRENT HOUR Setting of current hour 3 CURRENT MINUTES Setting of current minutes SET MENU In this group...

Page 28: ...codes only Only device s manufacturer or service technician have access to them Total and average consumption can be reseted by using a code 001 on Set Service menu Parameter s description No Paramete...

Page 29: ...ing warranty services are met Terms of acknowledging the warranty claims 1 The warranty is valid only when the user can provide an original invoice or purchase receipt for this device 2 The faulty pro...

Page 30: ...elf 4 Damages cased during transport due to inappropriate packaging 5 Damages caused by mechanical impact being struck by lightning flooding fire over voltage or other causes independent of the manufa...

Page 31: ...JUMAR REG 03 Mini NOTES 31...

Reviews: