JUMAR REG-03TFT
ALARMS
If the sensor is damaged or it is not connected, the temperature display will show a "
–-
"
image along with giving sound alarm. The alarm is switched off automatically after
failure removal (connecting the sensor or replacing it with a new one). The figure below
visualized an exemplary screen informing about missing sensor or sensor damage:
The alarm will be also activated, if the temperature exceeds safe value (90ºC).
Exceeding the temperature causes the burner to stop and switch into damping mode.
The burner's operation is blocked. The display will show the following message:
STB alarm has to be reseted manually after decreasing the temperature blow critical
value.