8 Programming
42
8.13 Signal inputs
The input signal is selected, and the ranges
as well as the filter constants for each signal
input are determined here.
Display
Edit
Selection/input
with keys
Enter
Continue with
C1
E
C101
Select input channel:
C101 channel 1
C102 channel 2
C103 channel 3
h
E
⇒
2n
with n = 1 — 3
⇒
2n
C111
C112
C113
E
CA00
Select input signal:
CA00 voltage
Cb00 current
h
E
Voltage
⇒
31n
Current
⇒
41n
Voltage:
⇒
31n
CA11
CA12
CA13
E
1
Select unit:
0 (mV)
1 (V)
h
E
⇒
32n
⇒
32n
CA21
CA22
CA23
E
0.000
Enter range start
h
,
l
,
S
E
check
range start
(–10.0V
≤
range start
< 10.0V or
0.0V
≤
range start
< 22.0V)
⇒
33n