11 Fault finding
11.1 What to do if...
Fibre pens on 0%
- The value is outside the measuring range
(Out Of Range)
- The transducer has been connected incorrectly
- The signal inputs are configured incorrectly
- Sensor break
No recording
- Key
S
has been pressed
Section 6.1
- The chart cassette has not been fitted correctly
Section 9.2
Caution: Insert the chart cassette by applying light up-
wards pressure
- The take-up roll has not properly engaged with the chart
cassette
Section 9.2.1
- The end of the chart has been reached
Section 9.2.1, Section 9.2.2
- The chart speed has been programmed as 0 mm/h
Section 8.3
Fibre pen does not write
- The fibre pen has not been fitted correctly
Section 5.4
- The fibre pen has run out of ink
No chart feed
- The chart cassette has not been fitted correctly
Section 9.2
- The chart has not been fitted correctly
- The chart speed has been programmed as 0mm/h
- The pin roller does not engage with the chart perforations
- The tear-off edge in not correctly engaged
- The pen recorder is in the STOP status
Measurements are not
recorded
- Check that the connecting terminals are tightened properly
- Check the supply
- Check the input configuration (range)
- Check the transducers and their cables, measure them
where appropriate
Summary of Contents for Logoline 500 junior
Page 1: ...Pen recorder with text printing B 95 3535 Operating Manual 4 99 00351782...
Page 12: ...2 Identifying the instrument version 10...
Page 46: ...8 Programming 44...
Page 48: ...9 Consumables 46 9 2 Removing and replacing the chart cassette...
Page 49: ...9 Consumables 47 9 2 1 Changing the roll chart 1 5 2 6 3 7 4 8...
Page 50: ...9 Consumables 48 9 2 2 Changing the fanfold chart 1 4 2 5 3 5 cm 10 cm 15 cm 1 m ENDE END FIN...
Page 51: ...49 10 Accessories 10 1 Converting the chart cassette 1 3 2 4...
Page 52: ...10 Accessories 50...
Page 54: ...11 Fault finding 52...
Page 61: ......
Page 62: ......
Page 63: ......