6189902 – Rev. C 07.2012
5
GB
Surface treatment:
Anodized aluminum
Purge Flow:
Set at 7 bar (102 psig)
Cycles (controlled by PLC):
2-3mins per column
Dryer Sizes:
The adsorption dryers are available in the following 3 sizes:
Dryer Size
Compressor Model
*Dew point @ 7bar
ADJ-050
(Q2)
OF302
2x OF302
OF1201
1000
2000
-40°C
-40°C
-40°C
-40°C
-40°C
ADJ-150
(Q3)
OF1202
2000
3x OF302
4000
-40°C
-40°C
-40°C
-40°C
ADJ-300
(Q6)
2x OF1202
6000
-40°C
-40°C
Figure 3
Note:
JUN-AIR reserves the right to change technical specifications.
*Dew Point is calculated at ambient temperature of 21°C, ambient
humidity of 20% and system pressure of 7 barg. Higher relative
humidity and lower ambient temperatures will negatively affect dew
point suppression.
Item #
Part Description
Qty
1
KNIT MESH - 31 x 5 mm
2
2
1/2” DIA 70 SHORE VITON BALL
2
3
GASKET SEAL
2
4
O-RING 1.78 Sec x 35 ID
4
5
O-RING 1.78 Sec x 19 ID
2
6
O-RING 2.0 Sec x 3 ID
2
7
PURGE SCREW
2
8
M4 x 12 CAP HEAD SCREW
4
9
M4 x 35 CAP HEAD SCREW
4
10
M4 x 18 CAP HEAD SCREW
4
11
M6 x 50 CAP HEAD SCREW
2
12
M6 x 25 CAP HEAD SCREW
16
13
M6 x 55 CAP HEAD SCREW
2
14
DIN 433 M6 FLAT WASHER
20
15
M4 ANTI VIBRATION WASHER
8
16
M4 FLAT WASHER
4
17
3/8 BSPP BLANKING PLUG
4
18
SOLENOID VALVE
2
19
EXTRUDED FASCIA
1
20
RATING PLATE
1
21
EXTRUSION
1
22
OUTLET PURGE BLOCK (12 BARG)
1
23
VALVE BLOCK
1
24
COMMON MANIFOLD
2
25
DRYER CARTRIDGE
2
Figure 4
Note: The dryer is supplied with all components shown on the list,
but only the components that require standard maintenance are
available in service kits provided by JUN-AIR.
Figure 5
Maintenance
WARNING! Installation and Service must be carried out by
authorized JUN-AIR distributors.
Make sure to depressurize air receiver and disconnect the unit
from electrical supply before removing any parts of the dryer and
compressor for service.