background image

LB management

Speed regulator

Speed regulator
Art. no.: 1735DS

Operating instructions

1

Safety instructions

Electrical devices may only be mounted and connected by electrically skilled persons.

Serious injuries, fire or property damage possible. Please read and follow manual fully.

Danger of electric shock. Always disconnect before carrying out work on the device or load.

Danger of electric shock. Device is not suitable for disconnection from supply voltage. The load
is not electrically isolated from the mains even when the device is switched off.

These instructions are an integral part of the product, and must remain with the end customer.

2

Intended use

Speed controller for controlling the speed of single-phase motors e.g. induction or shaded
pole motors

Mounting in appliance box according to DIN 49073

Operation with suitable cover

3

Product characteristics

Product characteristics

Device is operating in leading edge phase control

Operation without neutral conductor possible

Switch-on via soft start to maximum speed

Minimum speed can be saved permanently

Connection of extensions possible

Electronic short-circuit protection with permanent switch-off after approx. 100 ms

Electronic over-temperature protection

4

Operation

Switching motor or adjusting speed

The operation on the main device and the 3-wire rotary extension is identical.

Press the control button briefly: Motor switches on or off.

Turn the control button to the right: Speed is increased.

Turn the control button to the left: Speed is reduced.

Basic operation using 2-wire extension with push-button top or push-button

Press briefly: Motor switches on or off.

Press and hold: The speed is changed as long as the button is pressed, at maximum up
to the respective end value.

Push-button: The adjustment direction is changed with each new long actuation.

1 / 5

82404703

01.04.2021

J0082404703

Summary of Contents for 1735DS

Page 1: ...able cover 3 Product characteristics Product characteristics Device is operating in leading edge phase control Operation without neutral conductor possible Switch on via soft start to maximum speed Minimum speed can be saved permanently Connection of extensions possible Electronic short circuit protection with permanent switch off after approx 100 ms Electronic over temperature protection 4 Operat...

Page 2: ...L 4 2 1 5 6 3 Figure 1 Connection diagram with optional extensions 1 Button Test 2 LED display 3 Rotary axle 4 3 wire rotary extension 5 2 wire extension 6 Push button NO contact The connection of a central extension is not possible Operation without neutral conductor possible Only connect illuminated push buttons if they have a separate N terminal Precondition The maximum motor current Imax must ...

Page 3: ...d tools for the work Cover up live parts in the working environ ment The minimum speed must be set so that the motor does not stop at the lowest speed set ting Prerequisites Speed controller is ready for operation and the central plate is not mounted Press the button Test 1 until LED 2 lights up The current operating state remains the same After 45 seconds without an actuation the LED 2 goes out a...

Page 4: ...eed is too high Reduce the minimum speed Speed controller has switched off and cannot be switched on again Cause 1 overheating protection has tripped Reduce the connected load Disconnect the speed controller from the mains by switching off the circuit breaker Let the speed controller cool down for at least 15 minutes Switch on the circuit breaker and speed controller again Cause 2 short circuit pr...

Page 5: ...anagement Speed regulator ALBRECHT JUNG GMBH CO KG Volmestraße 1 58579 Schalksmühle GERMANY Telefon 49 2355 806 0 Telefax 49 2355 806 204 kundencenter jung de www jung de 5 5 82404703 01 04 2021 J0082404703 ...

Reviews: