LB management
Universal timer Bluetooth
Parameters
Setting options
Default setting
Explanations
Operating mode
Roller shutter
Venetian blind
Awning
Default setting: Roller shut-
ter
Roller shutter
A rolling shutter or an awning is controlled for
which the Fabric stretching function is re-
quired.
Venetian blind
A Venetian blind is controlled.
Awning
An awning is controlled for which the Fabric
stretching function is required.
Blind/shutter
ventilation posi-
tion
0 ... 100 %
Default setting: 100%
The blind/shutter stops in this position when
shutting down.
Slat ventilation
position
0 ... 100 %
Default setting: 100%
In the "Venetian blind" operating mode, the
opening angle of the Venetian blind slats for
the ventilation position can be influenced here.
Wind alarm Off
On, Off
Default setting: Off
Off:
If the disabling function is active, extension op-
eration in the "UP" direction (wind alarm) con-
tinues to be possible.
On:
If the disabling function is active, extension op-
eration is no longer possible. Note: Should not
be used in systems where wind alarm takes
place via an extension.
Settings with optional brightness temperature sensor
Parameters
Setting options
Default setting
Explanations
Sun protection
function
On, Off
Default setting: Off
If the sun protection function is switched on
and the brightness of the sun protection is ex-
ceeded for more than 2 minutes, sun protec-
tion is carried out. If the brightness falls below
the set sun protection brightness for more than
15 minutes, the sun protection end action is
carried out.
Sun protection
brightness
4,000 ... 80,000 lux
Default setting: 20,000 lux
Brightness threshold to carry out sun protec-
tion
Temperature
control
On, Off
Default setting: Off
If temperature control is activated, before im-
plementing the sun protection, the preset tem-
perature threshold is checked to see if it was
exceeded. If this is not the case, the sun pro-
tection is implemented only when the temper-
ature exceeds.
Sun protection
temperature
5 ... 50 °C, Off
Default setting: Off
Temperature threshold to carry out sun protec-
tion.
8 / 10
32598103
02.10.2019
J0082598103