background image

Resolution

Accuracy

± 10 % (laminar wind stream)

Wind speed sensor
Measuring range

approx. 0 ... 40 m/s

Resolution

0.1 m/s

Accuracy (≤ 10 m/s)

± 1 m/s

Accuracy (>10 m/s)

± 5 %

i

Accuracy as RMS average value over 360°.

Temperature sensor
Measuring range

-30 ... +60 °C

Resolution

0.1 K

Accuracy

± 1 C (Wind > 2 m/s, for -5 ... +25 °C)

Precipitation sensor
Measuring range

yes/no

Accuracy

Fine drizzle

Brightness sensors
Number

4

Measuring range

approx. 0 ... 150 klx

Resolution

0.1 klx

Accuracy

± 3 %

Spectral range

475 ... 650 nm

Twilight sensor
Measuring range

approx. 0 ... 900 lx

Resolution

1 lx

Accuracy

± 10 lx

Air pressure sensor
Measuring range

300 ... 1100 hPa

Resolution

0.01 hPa

Accuracy

± 0.5 hPa (20°C)

Humidity sensor
Measuring range

0 ... 100 % rel. humidity

Resolution

0.1 % rel. humidity

Accuracy

± 10 % rel. humidity (20°C)

abs. humidity

0 ... 400 g/m³

Resolution

0.01 g/m³

Global radiation
Measuring range

0 ... 1300 Watt/m²

Resolution

1 Watt/m²

Accuracy

± 10 %

Spectral range

350 ... 1100 nm

i

All accuracy specifications relate to the respective measuring range end value.

5.2 Accessories

Power supply AC 24 V ~

Art. No. WSSV10

5.3 Warranty

We reserve the right to make technical and formal changes to the product in the interest of
technical progress.
We provide a warranty as provided for by law.
Please send the device with a description of the defect to our central customer service office.

8/9

82590103
J:0082590103

30.01.2015

Universal weather station

Summary of Contents for 2225 WS U

Page 1: ...and fitted by electrically skilled persons Serious injuries fire or property damage possible Please read and follow manual fully These instructions are an integral part of the product and must remain...

Page 2: ...evaluation of weather data Wind speed Wind direction Precipitation Brightness Global radiation Twilight Temperature Relative air humidity and Air pressure Installation on the outside of buildings pref...

Page 3: ...1 Fitting and electrical connection Selecting the installation location Figure 3 Minimum distance to surfaces Figure 4 Avoid spray water 3 9 82590103 J 0082590103 30 01 2015 Universal weather station...

Page 4: ...weather station will be accessible In the case of flat roofs locate the weather station as close to the centre of the roof as possible Minimum distance to surfaces below the weather station 0 6 m fig...

Page 5: ...se clamps are suitable up to a maximum mast diameter of 60 mm i If mounted on the supplied fastening arm do not mount the enclosed guide blade o Mast mounting Attach fastening arm to mounting mast usi...

Page 6: ...24 V brown GND i The sensor head is translucent Therefore do not stick or write on the sensor head Aligning the device Figure 9 Orienting the weather station o Align the sensor head in the appropriate...

Page 7: ...ical data Supply Rated voltage AC 24 V SELV 10 Rated voltage DC 21 32 V SELV Current consumption 100 400 mA dependent on the weather Protection class III Connection cable Cable type LiYCY 4xAWG26 Cabl...

Page 8: ...g range 300 1100 hPa Resolution 0 01 hPa Accuracy 0 5 hPa 20 C Humidity sensor Measuring range 0 100 rel humidity Resolution 0 1 rel humidity Accuracy 10 rel humidity 20 C abs humidity 0 400 g m Resol...

Page 9: ...mestra e 1 58579 Schalksm hle Telefon 49 23 55 8 06 0 Telefax 49 23 55 8 06 2 04 kundencenter jung de www jung de Service Center Kupferstr 17 19 44532 L nen Germany 9 9 82590103 J 0082590103 30 01 201...