4 Information for electrically skilled persons
4.1 Fitting and electrical connection
Selecting the installation location
Figure 3: Detection planes
At an installation height of 1.10 m the motion detector has a detection field with an aperture
angle of 180° in 2 planes (figure 5).
Figure 4: Detection area
Size of the detection field: approx. 10 m x 12 m, semi-oval (figure 5). The information on the
size of the detection field refer to an installation height of 1.10 m. The nominal range varies for
different installation heights.
i
The orientation of the upper lens plate does not limit the detection field in space. Therefore
in some circumstances even motions outside of the specified detection field may trigger
switching operations.
Several basic principles must be taken into account when selecting the installation location.
o
Select a vibration-free installation location; vibrations can lead to unwanted switching.
3/8
32552843
J0082552843
16.08.2016
Radio Management
Radio automatic switch 180°