Extended channel settings "dimming"

Parameters

Setting options, Basic
setting

Explanations

Operating mode

Normal operation
Continuous on
Continuous off
Basic setting: Normal
Operation

see Device and channels

Manual commissioning

On, Off
Basic setting: On

Blocks manual commissioning
for the device channel.
Note: In the "Off" setting, the
device cannot be reset to the
factory setting.

Local Operation

On, Off
Basic setting: On

Blocks the output for operation
using the 

Prog

 button.

Behaviour on voltage return

 On
 Off
Last value
Configured brightness
Basic setting: Off

Defines the behaviour of the
output after voltage return.

Brightness on voltage return

0...100 %
Basic setting: 100 %

Brightness value, set by the
output after voltage return
(mains voltage). The
parameter "Behaviour after
voltage return" must be set to
"Configured brightness".
Note: If the value is above the
set maximum brightness or
below the minimum
brightness, then the system
will switch to the appropriate
limit value.

Behaviour after the end of the
disabling function

 On
 Off
no change
Last value
Basic setting: No change

Behaviour of the output when
a block is removed.

Manual saving of the scene
values

On, Off
Basic setting: On

Disables the saving of the
current brightness value as
scene value in an actuator for
a command via a transmitter.

8/15

32582723
J0082582723

27.04.2017

eNet radio centre plate

Summary of Contents for FM Series

Page 1: ...c shock The device is not suitable for disconnection from supply voltage Depending on the insert used the load is not electrically isolated from the mains even when the device is switched off These instructions are an integral part of the product and must remain with the end customer 2 Device components Figure 1 Device components 1 FM insert 2 Frame 3 Radio button 4 Status LED 3 Function Intended ...

Page 2: ...takes place with radio transmitters please observe the radio transmitter instructions Switch light o Press button for less than 0 4 seconds The light is switched on or off In combination with inserts for dimming switch on takes place at the saved switch on brightness Status LED 4 lights up output is switched on Status LED 4 off output is switched off i In the case of the HVAC insert only the outpu...

Page 3: ...istance from any possible sources of interference e g metallic surfaces microwave ovens hi fi and TV systems ballasts or transformers The flush mounted insert is correctly fitted and connected see instructions for flush mounted insert o Fit radio button 3 and frame 2 on flush mounted insert 1 o Switch on mains voltage o Carry out commissioning see Commissioning chapter 5 2 Commissioning DANGER Ele...

Page 4: ...s of a radio transmitter are disconnected automatically as soon as the last connection to the radio transmitter is disconnected Manual disconnection is not possible Resetting button to the default setting All connections to radio transmitters are disconnected and parameters are reset to default setting i The connections in the radio transmitters are preserved and must be deleted separately Load is...

Page 5: ...nuous on Continuous off Basic setting Normal Operation Normal operation The output can be operated with radio transmitters and the Prog button Continuous on The output switches to continuously On All operations of radio transmitters and the Prog button are ignored Continuous off The output switches to continuously Off All operations of radio transmitters and the Prog button are ignored Advanced de...

Page 6: ... time 1 60 s Basic setting 4 s Time from minimum brightness until reaching maximum brightness dimming speed Switch on delay 0 s 24 h Basic setting 0 s The load switches on after a delay Repeated switch on commands restart the delay time If the load has not yet been switched on due to the delay when a switch off command comes then the load will remain off Note The set time apply to operation using ...

Page 7: ...red the actuator will no longer remain on permanently but only for the length of the run on time The run on time is restarted if actuation is repeated This parameter is directly connected to the Manual switch off of run on time parameter Note The set time apply to operation using radio transmitters The device is switched immediately when the Prog button is pressed Manual switch off of the run on t...

Page 8: ...iour of the output after voltage return Brightness on voltage return 0 100 Basic setting 100 Brightness value set by the output after voltage return mains voltage The parameter Behaviour after voltage return must be set to Configured brightness Note If the value is above the set maximum brightness or below the minimum brightness then the system will switch to the appropriate limit value Behaviour ...

Page 9: ...ss value 0 100 Basic setting 0 Defines the behaviour of the output on activating the lock out protection Deactivate lock out protection brightness value 0 100 Basic setting 0 Defines the behaviour of the output on deactivating the lock out protection Only visible when the priority for the lock out protection is 0 Priority restraint 0 4 Basic setting 2 Specifies the priority for recalling and remov...

Page 10: ...of the output on activating the twilight function Deactivate twilight brightness value 0 100 Basic setting 0 Defines the behaviour of the output on deactivating the twilight function Only visible when the priority for the twilight function is 0 Switch off brightness overshoot On Off Basic setting On Allows automatic switch off according to the brightness If the parameter is On then the light contr...

Page 11: ...device is switched immediately when the Prog button is pressed Switch off delay 0 s 24 h Basic setting 0 s The load switches off after a delay Repeated switch off commands restart the delay time If the load has not yet been switched off due to the delay when a switch on command comes then the load will remain on Note The set time apply to operation using radio transmitters The device is switched i...

Page 12: ...n Continuous on Continuous off Basic setting Normal Operation see Device and channels Manual commissioning On Off Basic setting On Blocks manual commissioning for the device channel Note In the Off setting the device cannot be reset to the factory setting Local Operation On Off Basic setting On Blocks the output for operation using the Prog button Behaviour on voltage return On Off Last value Basi...

Page 13: ...ate On Off Basic setting Off Defines the behaviour of the output on activating the lock out protection Deactivate lock out protection switching state On Off Basic setting Off Defines the behaviour of the output on deactivating the lock out protection Only visible when the priority for the lock out protection is 0 Priority restraint 0 4 Basic setting 2 Specifies the priority for recalling and remov...

Page 14: ... state On Off Basic setting Off Defines the behaviour of the output on deactivating the twilight function Only visible when the priority for the twilight function is 0 Information window In the Information window the load can be controlled and the information about the device can be displays Channel control channel information Display value Explanations Current dimming value The load can be dimmed...

Page 15: ... in between the legal framework as provided for by law ALBRECHT JUNG GMBH CO KG Volmestraße 1 58579 Schalksmühle GERMANY Telefon 49 2355 806 0 Telefax 49 2355 806 204 kundencenter jung de www jung de 15 15 32582723 J0082582723 27 04 2017 eNet radio centre plate ...

Reviews: