eNet radio switch/push-button actuator in SCHUKO housing

Parameters

Setting options, Basic setting

Explanations

Deactivate wind alarm switch-
ing state

On, Off
Basic setting: Off

Defines the behaviour of the
output on deactivating the
wind alarm. Only visible when
the priority for the wind alarm
is 0.

Priority, sun protection

0...4
Basic setting: 0

Specifies the priority for recall-
ing and removing a scene of
type Sun protection for the
channel.

Activate sun protection switch-
ing state

On, Off
Basic setting: On

Defines the behaviour of the
output on deactivating the sun
protection. Only visible when
the priority for the sun protec-
tion is 0.

Deactivate sun protection
switching state

On, Off
Basic setting: Off

Defines the behaviour of the
output on deactivating the sun
protection. Only visible when
the priority for the sun protec-
tion is 0.

Priority, twilight

0...4
Basic setting: 0

Specifies the priority for recall-
ing and removing a scene of
type Twilight for the channel.

Activate twilight switching
state

On, Off
Basic setting: On

Defines the behaviour of the
output on activating the twi-
light function.

Deactivate twilight switching
state

On, Off
Basic setting: Off

Defines the behaviour of the
output on deactivating the twi-
light function. Only visible
when the priority for the twi-
light function is 0.

Switch off brightness over-
shoot

On, Off
Basic setting: On

Allows automatic switch-off
according to the brightness. If
the parameter is On, then the
light controller switches off
automatically when the bright-
ness setpoint is greatly ex-
ceeded. This parameter is not
yet active, as a light controller
has not yet been implemen-
ted.

Switch on brightness under-
shoot

On, Off
Basic setting: Off

Allows automatic switch-on
according to the brightness. If
the parameter is On, then the
light controller switches on
automatically when the bright-
ness setpoint is greatly under-
shot. We recommend only us-
ing the parameter in connec-
tion with the parameter
"Switch-off on brightness over-
shoot". This parameter is not

9 / 10

82592223

15.12.2020

J0082592223

Summary of Contents for FMAS10ZS

Page 1: ...ains voltage may be present on the load because only 1 pole is switched off Adapter plugs may not be connected in series and must be easily accessible The radio communication takes place via a non exclusively available transmission path and is therefore not suitable for safety related applications such as emergency stop and emergency call These instructions are an integral part of the product and ...

Page 2: ...date of the device software Reading of error memory Behaviour after mains voltage return The response after mains voltage return can be configured with the eNet server Default setting Off 4 Operation When operating with the eNet Server operation and signalling could vary from what is de scribed here Operation with radio transmitters Operation is with radio transmitters please observe the radio tra...

Page 3: ...sful All the memory locations in the actuator or radio transmitter are occupied All On and All Off buttons of a radio transmitter are connected to the actuator automatic ally as soon as the first connection to the radio transmitter takes place Scene buttons must be connected separately Disconnecting connection to a radio transmitter Carry out the same steps as when connecting see Connecting actuat...

Page 4: ... transformers 1500 W Inductive transformers 1000 VA HV LED lamps typ 500 W Compact fl lamp typ 500 W Fluorescent lamps uncompensated 920 VA Capacitive load 690 VA 560 μF Dimensions W H D 57 142 78 mm Radio frequency 868 0 868 6 MHz Transmission capacity max 20 mW Transmitting range in free field typ 100 m Receiver category 2 7 Parameter list The device parameters can be changed with the eNet serve...

Page 5: ...ed flashing Switch on starts flashing and switch off stops flashing The default flash frequency is 1 Hz This frequency is also the maximum flash frequency The flash frequency can be changed using parameters The parameter Switch off delay is used for the pulse time and the parameter Switch on delay for the pause time Continuous on The output switches to con tinuously On All operations of radio tran...

Page 6: ...ely when the Prog button is pressed Switch off delay 0 s 24 h Basic setting 0 s The load switches off after a delay Repeated switch off commands restart the delay time If the load has not yet been switched off due to the delay when a switch on com mand comes then the load will remain on In Flashing operating mode the pulse times are set using this parameter Comment The set times apply to operation...

Page 7: ...ters Setting options Basic setting Explanations Operating mode Switching operation Push button operation flashing Continuous on Continuous off Basic setting Switching oper ation See Device and channels Manual commissioning On Off Basic setting On Blocks manual commissioning for the device channel In the Off setting the device can not be reset to the factory set ting Local Operation On Off Basic se...

Page 8: ...Activate lock out protection switching state On Off Basic setting Off Defines the behaviour of the output on activating the lock out protection Deactivate lock out protection switching state On Off Basic setting Off Defines the behaviour of the output on deactivating the lock out protection Only vis ible when the priority for the lock out protection is 0 Priority restraint 0 4 Basic setting 2 Spec...

Page 9: ... removing a scene of type Twilight for the channel Activate twilight switching state On Off Basic setting On Defines the behaviour of the output on activating the twi light function Deactivate twilight switching state On Off Basic setting Off Defines the behaviour of the output on deactivating the twi light function Only visible when the priority for the twi light function is 0 Switch off brightne...

Page 10: ... channel selection in the Information window the following settings can be made or val ues displayed Display value Explanations Load state The load can be switched on or off Restraint Display of forced position status Operating hours Display of the operating hours since the last restart in the Settings window Einstellungen 8 Conformity Hereby Albrecht Jung GmbH Co KG declares that the radio system...

Reviews: