KNX IP router 

KNX IP router 

Art.-No.: IPR 100 REG 

Operationsmanual 

1 Safety instructions 

Electrical equipment may only be installed and fitted by electrically skilled persons. 

Failure to observe the instructions may cause damage to the device and result in fire and 
other hazards. 

Use the safety transformer according to DIN EN 61558-2-6 (VDE 0570 Part 2-6) or bell 
transformer according to DIN EN 61558-2-8 (VDE 0570 Part 2-8). 

These instructions are an integral part of the product, and must remain with the end 
customer. 

2 Device components 

Status LED (fig. 1) 

picture 1 

(1)  RUN, green, ready for operation 
(2)  LINE, yellow, data reception on the KNX line 
(3)  TX, red, Ethernet Transmit Signal, lit up/flashing during active transmission to the IP 

network 

(4)  RX, yellow, Ethernet Receive Signal, lit up/flashing during reception of valid IP telegrams 
(5)  LK, green, Ethernet Link Signal, lit up when there is an active connection to the IP network 

3 Function 

System information 

This device is a product of the KNX system and complies with the KNX directives. Detailed 
technical knowledge obtained in KNX training courses is a prerequisite to proper 
understanding.  
The function of this device depends upon the software. Detailed information on loadable 
software and attainable functionality as well as the software itself can be obtained from the 
manufacturer´s product database. Planning, installation and commissioning of the device are 
carried out with the aid of KNX-certified software. The latest versions of product database and 
the technical descriptions are available on our website. 

1/5 

82561723 
J:0082561723 

16.03.2010 

Summary of Contents for IPR 100 REG

Page 1: ... active transmission to the IP network 4 RX yellow Ethernet Receive Signal lit up flashing during reception of valid IP telegrams 5 LK green Ethernet Link Signal lit up when there is an active connection to the IP network 3 Function System information This device is a product of the KNX system and complies with the KNX directives Detailed technical knowledge obtained in KNX training courses is a p...

Page 2: ...neling Max 4 connections to IP end devices e g for simultaneous visualisation and configuration Failure message of the KNX system to the IP system Supply from network cable Power over Ethernet according to IEEE 802 3af via separate power supply accessory or the auxiliary voltage output of the KNX power supply Electrical separation between KNX and the IP network 4 Information for electrically skill...

Page 3: ...coupler no other line backbone coupler may be operated in the same segment Use commissioning software from ETS2 version 1 2 onwards i When ETS3 is used install the additional KNXnet IP driver The bus monitor and download functions are not supported in the local device o Press the programming button 9 The programming LED 10 is illuminated o Assign physical address The programming LED 10 is extingui...

Page 4: ...ical data Power over Ethernet supply Power over Ethernet IEEE802 3af Rated voltage DC 48 V Power consumption max 0 8 W External supply Rated voltage AC 12 24 V SELV Rated voltage DC 12 30 V SELV Power consumption max 1 7 W Connection of power supply Connection terminal Ambient conditions Ambient temperature 5 45 C Storage transport temperature 25 70 C Safety class III Relative humidity 5 93 No moi...

Page 5: ...Telefax 49 0 23 55 80 61 89 mail vka jung de General equipment Service Line 49 0 23 55 80 65 55 Telefax 49 0 23 55 80 62 55 mail vkm jung de KNX equipment Service Line 49 0 23 55 80 65 56 Telefax 49 0 23 55 80 62 55 mail vkm jung de The Œ symbol is a free trade symbol which is solely intended for the authorities and does not guarantee any properties ALBRECHT JUNG GMBH CO KG Volmestraße 1 D 58579 S...

Reviews: