background image

Art.-No.:  4071.0x LED, 4072.0x LED 
Art.-No.:  8471.0x LED W, 8472.0x LED W 

4 Software description 

4.1 Software specification 

ETS search paths: 

- Push-button / Push-button, 1-gang / Push-button BCU
- Push-button / Push-button, 2-gang / Push-button BCU

- Push-button / Push-button, 1-gang / Push-button BCU IP44
- Push-button / Push-button, 2-gang / Push-button BCU IP44

Configuration: 

S-mode standard 

PEI type: 

"00"

Hex

 / "0" 

Dec 

PEI connector:  

No connector 

Application for the push-button bus coupler 1-gang switch position 

No.  Short description 

Name 

Version 

from mask 
version 

Push-button bus coupler application 
with one one-sided operated control 
surface
(1 x button). 

Switching, dimming, 
Venetian blind, 
value, scene 
10FA11 

1.1
for ETS3.0 
Version d  
onwards
patch A or 
ETS4

705 

Application for the push-button bus coupler 1-gang neutral position 

No.  Short description 

Name 

Version 

from mask 
version 

Push-button bus coupler application 
with one two-sided operated control 
surface
(1 x rocker switch or 2 x button). 

Switching, dimming, 
Venetian blind, 
value, scene 
10FB11 

1.1
for ETS3.0 
Version d  
onwards
patch A or 
ETS4

705 

Application for the push-button bus coupler 2-gang button position 

No.  Short description 

Name 

Version 

from mask 
version 

Push-button bus coupler application 
with two one-sided operated control 
surfaces
(2 x button). 

Switching, dimming, 
Venetian blind, 
value, scene 
10FC11 

1.1
for ETS3.0 
Version d  
onwards
patch A or 
ETS4

705 

Page 10 of 34 

  

Software specification 

Summary of Contents for KNX 4071.0 LED Series

Page 1: ...sh button BCU IP44 Art No 8471 0x LED W 8472 0x LED W ALBRECHT JUNG GMBH CO KG Volmestraße 1 58579 Schalksmühle Telefon 49 23 55 8 06 0 Telefax 49 23 55 8 06 2 04 kundencenter jung de www jung de Service Center Kupferstr 17 19 44532 Lünen Germany Issue 10 05 2012 629x2y2z ...

Page 2: ...nnection 6 2 4 Commissioning 7 2 5 Operation 8 3 Technical data 9 4 Software description 10 4 1 Software specification 10 4 2 Software 10Fx11 12 4 2 1 Scope of functions 12 4 2 2 Notes on software 14 4 2 3 Object table 15 4 2 4 Functional description 19 4 2 4 1 Rocker switch and button arrangement 19 4 2 4 2 Rockers and button functions 20 4 2 4 3 Status LED 23 4 2 4 4 Delivery state 24 4 2 5 Para...

Page 3: ...ssed In the switch position version the rocker switch can only be operated on one side e g at the bottom so that only push button functions are executable In this case the rocker switch is slanting when it is not pressed In the ETS the KNX functions Switching Dimming and Venetian blind are configurable for rocker switch operation concepts In the pushbutton control concepts the KNX functions Switch...

Page 4: ...ust be observed Failure to observe the instructions may cause damage to the device and result in fire and other hazards Make sure during the installation that there is always sufficient insulation between the mains voltage and the bus A minimum distance of at least 4 mm must be maintained between bus conductors and mains voltage cores The device may not be opened or operated outside the technical ...

Page 5: ...ed variant Figure 2 2 gang device component version example as flush mounted variant 1 Programming button with LED 2 Status LED 3 Sockets for design operating rockers i In the 1 gang device version rocker switches are used In the 2 gang device version two circuit switching rockers are used Page 5 of 34 Installation electrical connection and operation ...

Page 6: ... the back of the device o Install the device in the right orientation on an appliance box Observe the marking OBEN TOP With SM device version no figure o Install the SM appliance box on the wall Insert the bus line into the appliance box and connect to the bus connection at the back of the push button insert using the terminal o Insert the push button insert carefully into the SM appliance box Whe...

Page 7: ...ed and ready for use An appropriate device must be created and configured in the ETS project The programming button is located on the front of the device see chapter 2 2 Device components Before final fitting of the rocker covers the physical address has to be loaded into the device o Activating Programming mode press the programming button 1 The programming LED lights up red o Program the physica...

Page 8: ...e rocker switch can only be operated on one side e g at the bottom so that only push button functions are executable In this case the rocker switch is slanting when it is not pressed The ETS configuration has a significant influence over the function of the device In the neutral position device version the operation concept can be configured to rocker switch function the same KNX function on both ...

Page 9: ...oval KNX EIB Ambient temperature 25 55 C Storage transport temperature 25 70 C Relative humidity 5 93 No moisture condensation KNX EIB supply KNX medium TP 1 Commissioning mode S mode Rated voltage KNX DC 21 32 V SELV Power consumption KNX typical 150 mW Connection mode KNX Connection terminal Page 9 of 34 Technical data ...

Page 10: ...e 1 x button Switching dimming Venetian blind value scene 10FA11 1 1 for ETS3 0 Version d onwards patch A or ETS4 705 Application for the push button bus coupler 1 gang neutral position No Short description Name Version from mask version 1 Push button bus coupler application with one two sided operated control surface 1 x rocker switch or 2 x button Switching dimming Venetian blind value scene 10F...

Page 11: ...utral position No Short description Name Version from mask version 1 Push button bus coupler application with two one sided operated control surfaces 2 x rocker switch 4 x button Switching dimming Venetian blind value scene 10FD11 1 1 for ETS3 0 Version d onwards patch A or ETS4 705 Page 11 of 34 Software specification ...

Page 12: ...ON OFF TOGGLE no reaction KNX Dimming function Available with rocker switches or button operation concept With rocker switch Command on pressing rocker switch at the top and at the bottom is configurable Brighter ON Brighter OFF Darker TOGGLE no reaction With button Command on pressing the buttons is configurable Brighter ON Darker OFF Brighter Darker TOGGLE Brighter TOGGLE Darker TOGGLE no reacti...

Page 13: ...generally In the neutral position device version the LED can also be used as a status indicator with the rocker switch operation concept In this case the LEDs have their own 1 bit communication objects for activation In the 1 gang push button bus coupler both LEDs always perform the same display function In the 2 gang device the LEDs can perform different functions independent of each other Page 1...

Page 14: ...n the ETS project matches the application program for the installed device hardware The ETS prevents the programming of application programs of devices with switch position in devices with neutral position or vice versa The ETS does not intercept the programming of an application program of the 1 gang device variant in a 2 gang device or vice versa Undesirable functions can result here due to miss...

Page 15: ...0 1 2 3 Function Switching Name Button 1 41 Type 1 bit DPT 1 xxx Flag C W T Description 1 bit object for transmission of switching telegrams ON OFF This object is only visible with button functions Objects for dimming Function Switching Object h 0 2 Function Switching Name Rocker 1 2 1 Type 1 bit DPT 1 xxx Flag C W T Description 1 bit object for transmission of switching telegrams ON OFF This obje...

Page 16: ...t time operation Name Rocker 1 2 1 Type 1 bit DPT 1 007 Flag C T Description 1 bit object for short time operation of a blind or roller shutter This object is only visible with rocker functions Function Venetian blind Object h 8 10 Function Long time operation Name Rocker 1 2 1 Type 1 bit DPT 1 008 Flag C W T Description 1 bit object for long time operation of a blind or roller shutter This object...

Page 17: ...er Object h 0 1 2 3 Function Value Name Button 1 4 1 Type 1 byte DPT 5 xxx Flag C T Description 1 byte object for the transmission of values from 0 to 255 0 100 This object is only visible with button functions Objects for scene extension Function Scene extension Object h 0 2 Function Scene extension Name Rocker 1 2 1 Type 1 byte DPT 18 001 Flag C T Description 1 byte object for recalling or for s...

Page 18: ...me LED left Type 1 bit DPT 1 xxx Flag C W Description 1 bit object for activation of the left status LED polarity configurable Only visible with the device version 2 gang neutral position and rocker switch operation concept and LED function equal to status indicator or inverted status indication Function Status LED Object h 17 Function Status indication Name LED right Type 1 bit DPT 1 xxx Flag C W...

Page 19: ...s on the control elements In the neutral position version the rocker switches are upright when they are not pressed In the switch position version 6 7 the rocker switch can only be operated on one side e g at the bottom so that only push button functions are executable In this case the rocker switch is slanting when it is not pressed The figure below shows the device variants and illustrates the p...

Page 20: ...ons are normally configured to single surface operation Rocker switches can also be configured in the ETS to the toggle command TOGGLE resulting in a large control surface with two actuation points that have functionally identical commands The parameters Command on pressing the button and Command on pressing the rocker switch top bottom define the single surface or double surface dimming function ...

Page 21: ...long time telegram after the end of T1 Move for the continuous movement of the drive No further telegram is transmitted by the device when the button or the rocker is released The drive remains on until the end position is reached Command of the Venetian blind function The parameters Command on pressing the button and Command on pressing the rocker switch define the command transmitted to the bus ...

Page 22: ...device monitors the length of the actuation A button press of less than a second results in a simple recall of the scene as mentioned above After a button press of more than five seconds the device generates a storage instruction and transmits a storage telegram to the bus according to KNX data type 18 001 An operation lasting between one and five seconds will be discarded as invalid The device th...

Page 23: ...ttons depends on the device variant see page 19 1 gang switch position Both status LEDs left and right light up on pressing button 1 1 gang neutral position Both status LEDs left and right light up on pressing the rocker switch 1 or buttons 1 and 2 2 gang switch position The left status LED lights up when on the button 1 the right status LED lights up on pressing button 2 2 gang neutral position T...

Page 24: ...on is pressed the corresponding status LED lights up for the length of the button press simple function test At the same time both status LEDs always light up simultaneously in the 1 gang device variant This condition persists until the application is programmed into the device by the ETS i Unloading of the application program by the ETS completely deactivates the device function In this case the ...

Page 25: ...arameter defines for the rocker switch 1 whether it is to be used as a rocker switch with a common basic function or as two different buttons with completely independent functions Depending on this setting the ETS displays different communication objects and parameter pages i This parameter is only visible in the device variant 2 gang neutral position Rocker 2 right Button function Rocker function...

Page 26: ...Brighter ON Darker OFF Brighter darker TOGGLE Brighter TOGGLE Darker TOGGLE This parameter defines the command on pressing the rocker switch briefly and long at the upper pressure point Command on pressing the bottom rocker No reaction Brighter ON Darker OFF Brighter darker TOGGLE Brighter TOGGLE Darker TOGGLE This parameter defines the command on pressing the rocker switch briefly and long at the...

Page 27: ...ram repeat Yes No This parameter can be used to activate telegram repetition for dimming With the rocker switch held down at the top or bottom the pushbutton sensor will then transmit the relative dimming telegrams in the programmed level width until the rocker button is released again Time between two telegrams 200 ms 300 ms 400 ms 500 ms 750 ms 1 sec 2 sec This parameter defines the interval at ...

Page 28: ...parameters and objects are visible depending on this parameter setting With Switching function Command on pressing the button No reaction ON OFF TOGGLE This parameter defines the command on pressing the button Command on releasing the button no reaction ON OFF TOGGLE This parameter defines the command on releasing the button With Dimming function Command on pressing the button No reaction Brighter...

Page 29: ... telegram for stopping the dimming process when the button is released When the device transmits telegrams for dimming in small steps the stop telegram is generally not needed setting No Telegram repeat Yes No This parameter can be used to activate telegram repetition for dimming With the button held down the device will then transmit the relative dimming telegrams in the programmed level width un...

Page 30: ...100 With Scene extension function Function Scene extension without storage function Scene extension with storage function In the setting Scene extension without storage function a button press triggers the simple recall of a scene The device then transmits the configured scene number immediately on pressing the button A long button press has no additional effect In the setting Scene extension with...

Page 31: ... the button or rocker is released i The KNX function Scene extension with storage function can particularly affect the status LED allocated to the actuated button If the status LED is configured to button press display the LED always lights up for the configured light period when the button is pressed 1 5 s When transmitting a storage telegram after pressing the button for a long time 5 s the stat...

Page 32: ...tton for a long time 5 s the status LED is additionally activated for 3 seconds in order to indicate that the storage instruction was transmitted to the bus Status indicator via LED object With this setting the status LED can indicate the state of a separate 1 bit communication object It is possible to switch the LED on or off statically via the 1 bit object value received object value 0 OFF 1 ON ...

Page 33: ...communication objects 15 D delivery state 24 device variants 19 Dimming 20 E ETS 7 14 ETS search paths 10 S Scene extension 22 Switching 20 V Value transmitter 21 Venetian blind 21 Art No 4071 0x LED 4072 0x LED Art No 8471 0x LED W 8472 0x LED W Page 33 of 34 Appendix ...

Page 34: ...71 0x LED W 8472 0x LED W ALBRECHT JUNG GMBH CO KG Volmestraße 1 58579 Schalksmühle Telefon 49 23 55 8 06 0 Telefax 49 23 55 8 06 2 04 kundencenter jung de www jung de Service Center Kupferstr 17 19 44532 Lünen Germany Page 34 of 34 Appendix ...

Reviews: