3 Function

System information

This device is a product of the KNX system and complies with the KNX directives. Detailed
technical knowledge obtained in KNX training courses is a prerequisite to proper understanding. 
The function of this device depends upon the software. Detailed information on loadable soft­
ware and attainable functionality as well as the software itself can be obtained from the
manufacturer´s product database. Planning, installation and commissioning of the device are
carried out with the aid of KNX­certified software. The latest versions of product database and
the technical descriptions are available on our website.

Intended use

­

Operation of loads, e.g. light on/off, dimming, blinds up/down, brightness values, tempera­
tures, calling up and saving light scenes, etc.

­

Measurement and feedback control of the room temperature

­

Mounting only in the wall box listed under Mounting

4 Operation

Operating a function or load

Depending on the programming, a button can have up to three functions assigned to it –
upper/left, lower/right, entire surface. Operation depends on the specific function. 

o

Switching: Short press on button.

o

Dimming: Long press on the button. The dimming process ends when the button is
released.

o

Move Venetian blind: Long press on button. 

o

Stop or adjust Venetian blind: Short press on button.

o

Call up light scene: Short press on button.

o

Save light scene: Long press on button.

o

Set value, e.g. brightness or temperature setpoint: Short press on button. 

Operating modes and icons

The device compares the current room temperature with the setpoint temperature and controls
heating or cooling devices according to the current demand. The setpoint temperature depends
on the current operating mode and can be changed by the user, depending on the program­
ming. The operating modes and the current controller status are shown in the display.

ó

: Operating mode Comfort

ô

: Operating mode Standby

õ

: Operating mode Night

ö

: Operating mode Frost/heat protection. At temperatures below 41 °F

(5 °C), the icon flashes.

÷

: Dew point operation display; controller is disabled

óõ

: Comfort extension Night

óö

: Comfort extension Frost protection

Ü

: Information mode is active. When the button is pressed, the display shows a text for the trig­

gered function.

òñ

...

: Fan controller with fan level display. 

ë

= Fan off.

ÝÞ

...

â

: Heating mode with display of the heating stage

ãä

...

è

: Cooling mode with display of the cooling

é

: Energy requirement; currently there is heating or cooling.

þ

: Operating display for switching channels 1...4 switched on: 

øùúû

 or 

ýüþ

Û

: Buttons disabled

0

: No setpoint shift

...– – 0

 or 

0 – –... 

: Setpoint temperature reduced or increased manually

2/8

Room controller display module 2-gang

82574805
J0082574805

29.06.2017

Summary of Contents for KNX 4092M-01

Page 1: ...4092M 01 Operating instructions 1 Safety instructions Figure 1 2 Device components Figure 2 1 Display 2 Text area 3 Buttons 1 and 2 4 Operating and status LED 5 Status icons Room controller display m...

Page 2: ...ove Venetian blind Long press on button o Stop or adjust Venetian blind Short press on button o Call up light scene Short press on button o Save light scene Long press on button o Set value e g bright...

Page 3: ...Comfort mode setpoint temperature Heating standby temperature reduction Cooling standby temperature increase Heating night reduction temperature reduction Cooling night reduction temperature increase...

Page 4: ...solid walls Dia 2 3 in depth 2 6 in 9064 01 For hollow walls Hole dia 2 67 in Depth 2 4 in i Wall boxes must be ordered separately o Wall boxes for solid walls have to be placed flush to the wall pla...

Page 5: ...Mount supporting frame 6 or 13 in the correct position onto a wall box Note marking TOP above marking A or B in front Use only the enclosed box screws 12 o Push frame 7 onto supporting frame o Push b...

Page 6: ...Push button extension module connecting cable 5 2 Commissioning Loading the physical address and application software Project design and commissioning with ETS3 0d with Patch A or more recent The dev...

Page 7: ...V SELV Current consumption KNX max 20 mA Connection mode KNX device connection terminal Ambient temperature 23 113 F 5 45 C Storage transport temperature 13 158 F 25 70 C Protection class III Purpose...

Page 8: ...ALBRECHT JUNG GMBH CO KG Volmestra e 1 58579 Schalksm hle GERMANY 8 8 Room controller display module 2 gang 82574805 J0082574805 29 06 2017...

Reviews: