background image

Product Information 

 

 

DCM Comfort indoor station  
TK IS xx x14 x 

 

 

ALBRECHT JUNG GMBH & CO. KG 

Volmestraße 1 
58579 Schalksmühle 

Phone +49.2355.806-0 
Fax +49.2355.806-189 

E-Mail: mail.info@jung.de  
Internet: gb.jung.de 

 

Summary of Contents for TK IS 14 Series

Page 1: ...oduct Information DCM Comfort indoor station TK IS xx x14 x ALBRECHT JUNG GMBH CO KG Volmestra e 1 58579 Schalksm hle Phone 49 2355 806 0 Fax 49 2355 806 189 E Mail mail info jung de Internet gb jung...

Page 2: ...14 Additional functions 15 Automatically hands free operation after internal call 15 Automatic floor door release control function 11 16 Resetting of the additional functions 16 Settings 17 Voice volu...

Page 3: ...uirements of DIN VDE 0100 must be observed When installing DCM BUS systems the general safety rules for telecommunication sys tems in accordance with VDE 0800 must be observed separate cabling for hig...

Page 4: ...door release main door automatic door release floor door function button switches lighting Basic settings Alternative assignment Control function internal call automatic door release call di version v...

Page 5: ...on LED indication a b c d e f g h red red blue red red red green red Ring tone setting mode Ring tone on off Operation LED Setting mode for function button Call diversion Automatic door release active...

Page 6: ...mode g flashing incoming door call g flashing fast communication occupied f flashing voice memo function new message Function button Activation of the assigned function Initiate the setting mode of t...

Page 7: ...Wiring example Connecting diagram Please observe cable length and loop resistance Floor bell button Floor bell button Indoor station Indoor station Outdoor station Power supply control unit Door relea...

Page 8: ...ted A B E P on the reverse side of the device Mounting For the connection of the device with the plastic screws 6 drilled holes of 6 x10 mm are required Please use the supporting frame to mark the hol...

Page 9: ...elected ring tone ring tone volume mute activated call diversion internal call automatic door release control functions and light switching and voice memo Factory settings Limited communication time a...

Page 10: ...g setting mode at indoor station IS1 Push function button for approx 8 s until you can hear acknowledge tone fast LED flashing release the function button fast LED flashing Push function button at BOT...

Page 11: ...elease the function button fast LED flashing Push function button at LEFT section acknowledge tone LED is illuminated for approx 3 s LED is OFF Target indoor station IS2 If green LED is illuminated pu...

Page 12: ...LED is OFF Now you can activate deactivate the automatic door release by means of pushing the function button Control function 8 Preparation DCM system is in idle mode Push function button for approx...

Page 13: ...factory settings Attention All settings are reset to factory settings Push ring tone button and function button for approx 8 s until you can hear acknowledge tone LED is illuminated for approx 3 s th...

Page 14: ...the IS 228515 With the following key combination IS 228520 operates parallel with IS 228515 99 228520 228515 Note Deleting the parallel function with ParSNr 0 99 228520 0 Ser Nr Serial number of the...

Page 15: ...t the call by means of pushing a button The person at the calling indoor station can directly start talking This function will be adjusted at the receiving indoor station Preparation DCM system is in...

Page 16: ...button for longer than 12 s After approx 8 s you can hear an acknowledge tone and the LED is flashing fast After further 4 s you can hear a second acknowl edge tone and the LED of the ring tone button...

Page 17: ...ON 0 5 s OFF fast LED flashing 0 125 s ON 0 125 s OFF LED illuminated LED pulse flashing 0 5 s ON 1 5 s OFF LED OFF short centrically pushing of button short pushing of button section push button unt...

Page 18: ...ume Push ring tone button at the TOP section for approx 1 s the voice volume increases Decrease voice volume Push ring tone button at the BOTTOM section for approx 1 s the voice volume decreases Repea...

Page 19: ...he desired volume is reached Average voice volume factory setting Push ring tone button LEFT or RIGHT Ring tone volume Preparation DCM system is in idle mode 8 voice volume levels can be adjusted for...

Page 20: ...paration DCM system is in idle mode Ring tone OFF Push ring tone button LEFT or RIGHT The LED is illuminated the ring tone is OFF Ring tone ON Push ring tone button LEFT or RIGHT the LED turns off the...

Page 21: ...ed outdoor station Ring tone 1 for Outdoor station 0 Preparation DCM system is in idle mode Push ring tone button for approx 8 s until you can hear acknowledge tone fast LED flashing Release the ring...

Page 22: ...t LED flashing Release the ring tone button The TOP LED of the ring tone button flashes fast Push ring tone button at the BOTTOM section You can hear the next ring tone Now this ring tone is selected...

Page 23: ...ED flashing Release the ring tone button The TOP LED of the ring tone button flashes fast Push ring tone button at the LEFT section You can hear the next ring tone Now this ring tone is selected for t...

Page 24: ...D flashing Release the ring tone button The TOP LED of the ring tone button flashes fast Push ring tone button at the RIGHT section You can hear the next ring tone Now this ring tone is selected for t...

Page 25: ...D starts fast pulse flashing Release the ring tone button Now the indoor station is ready for the following assignment Selection sub door call 1 Serial no 1 LED pulse flashing Push ring tone button at...

Page 26: ...at the action until the desired ring tone is selected Selection sub door call 4 Serial no 4 LED pulse flashing Push ring tone button at the RIGHT section You can hear the next ring tone Now this ring...

Page 27: ...n when the preset communication time of the outdoor station is elapsed factory setting 1min by means of pushing the door release button Start communication without incoming call This function can be d...

Page 28: ...oor release button to open the door Light switching Push the function button when function button is ad justed with light switching factory setting or When light switching function is activated Push t...

Page 29: ...tre then the additional control function 11 involves an other door release relay e g for the floor entrance door of the clinic centre This relay will be activated by means of pushing the floor bell bu...

Page 30: ...utton or Fast flashing of the TOP LED of ring tone button Note Push the communication button until your ring tone stops Push the communication button You can hear first acknowledge tone now the LED of...

Page 31: ...approx 8 s until you can hear acknowledge tone fast LED flashing release the ring tone button Fast flashing of the TOP LED of ring tone button Push communication button for approx 4 s until you can he...

Page 32: ...hear acknowledge tone after 8 s fast LED flashing release the ring tone button Fast flashing of the TOP LED of ring tone button Push communication button You can hear the first acknowledge tone now th...

Page 33: ...Push the communication button You can hear first acknowledge tone now the TOP LED of the communication button starts flashing with the second acknowledge tone starts the re cording time of the voice...

Page 34: ...s release the communication button The voice memo will be played After you played the voice memo the LED turns off You can play the voice memo again Delete voice memo Push communication button until...

Page 35: ...itching factory setting A bell button of the outdoor station will switch the light if the bell button is not assigned to an indoor station Light switching function Programming at the power supply and...

Page 36: ...talking time 60 s factory setting The talking time is adjustable Control function Command for the control of various relays in the door communica tion system Sub door call Programming only with the s...

Page 37: ...be doubled i e two lines are used for one wire figure The lines must be twisted When using screened cables connect the screens to each other and connect on one side to earth b wire on the power supply...

Page 38: ...Outdoor station IS Indoor station VS Power supply and control unit Technical data Supply voltage 24 V DC 8 Power supply control unit 24 V a b 26 V P b in idle state Current 3 wire I a 0 1 mA I P 6 5...

Page 39: ...L nen Germany Service Line 0 23 55 80 65 51 Fax 0 23 55 80 61 89 E Mail mail vka jung de Technique DCM Service Line 0 23 55 80 65 52 Fax 0 23 55 80 62 55 E Mail mail vka jung de Albrecht Jung GmbH Co...

Page 40: ......