1. Warning
Attention:
Electrical equipment must be installed and fitted only by qualified
electricians and in observance of the applicable accident prevention
regulations.
Not suitable for disconnecting.
When the universal dimmer
is off the load is not electrically isolated
from the mains.
When using conventional transformers, protect the primary side of
each transformer by a fuse as indicated by the manufacturer.
Do not connect any electronic lamps, e.g. switchable or dimmable
compact fluorescent lamps or LED lamps. Device can be damaged.
Only use safety transformers as per EN 61558-2-6.
Non-observance of the installation instructions may cause fire or
other hazards.
2. Function
Universal dimmer for switching and dimming extensive light sources such
as:
•
230 V incandescent lamps.
•
230 V halogen lamps.
•
LV halogen lamps in conjunction with TRONIC transformers
•
LV halogen lamps in conjunction with conventional transformers.
Switching and dimming commands are given when the covers of the
dimmer, of the extension insert or of the radio transmitter are actuated .
The universal dimmer works on the basis of the twoarea principle, i. e.
there is one touch area each for the ‘brighter’ and ‘darker’ dimming
directions. The lights are turned on by a lamp-saving soft start. This
Operating Instructions paper describes the functionality in combination
with the manual attachment.
Stand: Feb-10 325 274 43