digital audio
modular
processing system
C8000
64ch BNC MADI & AoIP I/O
C8315
20/20
GPO
s (Tallies) may signal the status of a module for
GPI
driven devices like legacy equipment
monitoring systems. The c8k frame can handle
127
different virtual (system)
GPO
numbers.
If an event occurs, the
C8315
puts the assigned number on the CAN bus so a
C8817
GPI/O
module
can engage a relay or the
brc8x
may activate its tallies.
Clear GPO on
If a GPO indicates that a certain preset is loaded and if you
Preset modified
change parameters which are related to that preset the word
"modified" will be displayed in line with the preset name in the
status window.
In this case you may clear that GPO to indicate that the
parameters are not the same as the content of the previously
loaded preset.
Important Note!
Virtual
GPI
and
GPO
numbers do not "see" each other on the CAN bus. I.e. you can not
use a
GPO
number to trigger an event inside the frame directly. If this is the task you
must
use the
C8817
GPI/O
module that can do the system
GPI/O
link-up that also provides you with the possibility to set up
logical combinations of physical and virtual (system)
GPI/Os
.