Fault
Possible Cause
Remedy
4917
– A key/ function-pre-
select key (wire
guidance on/off,
attachment traverse,
fork carriage
rotation) has been
pressed during
power-up test
– Do not press the key/ function-pre-
select key(wire guidance on/off,
attachment traverse, fork carriage
rotation); switch the truck off and on
again.
4918
– Dead man's switch
pressed during
power-up test
– Do not press the dead man's switch;
switch truck off and on again.
9901
– The personal-
protection-system
cycle test must be
performed
– Carry out the personal-protection-
system cycle test, see page 243.
9963
– Front screen of
personal protection
system (PPS) laser
scanner is dirty
– Clean the front screen of personal
protection system (PPS) laser scanner,
see page 243.
210
04.19 en-GB