29
02
.1
6
EN
9
Storing the battery
NOTE
The battery should not be stored for longer than 3 months without charging as
otherwise it will no longer be functional.
If the battery is to be taken out of service for a long period, it should be stored fully
charged in a dry room protected from frost. To ensure the availability of the battery
the following charges can be selected:
– Monthly compensation charge for PzS and PzB batteries or 4-monthly full charge
for PzV batteries.
– Trickle charge for a charging voltage of 2.23 V x number of cells for PzS, PzM and
PzB batteries or 2.25 V x number of cells for PzV batteries.
If the battery is to be taken out of service for a long period ( > 3 months), it should, as
far as possible, be charged to 50% of its charge level and stored in a dry room
protected from frost.
10
Troubleshooting
If any faults are found on the battery or charger, contact the manufacturer's customer
service department immediately.
Z
The operations required must be carried out by the manufacturer's customer
service department or a customer service organisation authorised by the
manufacturer.
11
Disposal
Batteries marked with the recycling symbol and the sign showing a
crossed-out rubbish bin should not be disposed of with ordinary
household waste.
Buy-back terms and type of recycling are to be agreed with the
manufacturer as described in § 8 of the battery legislation.
Summary of Contents for EFX 410
Page 1: ...EFX 410 413 03 13 Operating instructions 51296679 04 19 en GB EFX 410 EFX 413 ...
Page 2: ...2 ...
Page 4: ...4 04 19 en GB ...
Page 12: ...0506 GB 2 0506 GB 2 ...
Page 72: ...70 04 19 en GB ...
Page 90: ...88 04 19 en GB ...
Page 250: ...248 04 19 en GB ...
Page 261: ...The Operator specific settings menu now opens 259 04 19 en GB ...
Page 376: ......
Page 380: ...02 16 EN 6 ...
Page 382: ...02 16 EN 8 14 Safety instructions and warning information ...
Page 404: ......