6.6
Lower cutout override (
o
)
Z
If local conditions require, an automatic lower cutout can be installed to be activated
from a given height. The automatic lower cutout prevents the Main Lift from being
lowered. The driver's display shows the "Lower cutout override" symbol (183).
WARNING!
Placing the load handler can be hazardous
The lower cutout is an auxiliary function designed to support the operator which
however does not release him from his responsibility to stop hydraulic operations
e.g. when confronted with an obstacle.
u
When the lower cutout has been de-activated the truck must be operated with
extra care in order to detect obstacles when lowering the load handler.
u
Stop lowering the load handler before you reach the obstacle.
Z
Lower cutout only becomes effective after referencing has been carried out (see
page 147). When referencing has been completed, the height actual value is shown
in the driver's display.
ETX 5xx IF FNxxxx
07:48
P
0h
0,15 m
219
04.19 en-GB
Summary of Contents for EFX 410