29
02
.1
6
EN
9
Storing the battery
NOTE
The battery should not be stored for longer than 3 months without charging as
otherwise it will no longer be functional.
If the battery is to be taken out of service for a long period, it should be stored fully
charged in a dry room protected from frost. To ensure the availability of the battery
the following charges can be selected:
– Monthly compensation charge for PzS and PzB batteries or 4-monthly full charge
for PzV batteries.
– Trickle charge for a charging voltage of 2.23 V x number of cells for PzS, PzM and
PzB batteries or 2.25 V x number of cells for PzV batteries.
If the battery is to be taken out of service for a long period ( > 3 months), it should, as
far as possible, be charged to 50% of its charge level and stored in a dry room
protected from frost.
10
Troubleshooting
If any faults are found on the battery or charger, contact the manufacturer's customer
service department immediately.
Z
The operations required must be carried out by the manufacturer's customer
service department or a customer service organisation authorised by the
manufacturer.
11
Disposal
Batteries marked with the recycling symbol and the sign showing a
crossed-out rubbish bin should not be disposed of with ordinary
household waste.
Buy-back terms and type of recycling are to be agreed with the
manufacturer as described in § 8 of the battery legislation.
Summary of Contents for EJC 212z
Page 2: ...2 ...
Page 4: ...4 04 19 en GB ...
Page 10: ...10 04 19 en GB ...
Page 12: ...0506 GB 2 0506 GB 2 ...
Page 27: ...EJC 212z 214z 216z 220z D 25 04 19 en GB ...
Page 50: ...48 04 19 en GB ...
Page 74: ...72 04 19 en GB ...
Page 135: ...Z This setting can be changed if required 133 04 19 en GB ...
Page 193: ...Z After adding hydraulic oil tighten the lock to 10 Nm M 10Nm 191 04 19 en GB ...
Page 195: ...115 113 114 112 193 04 19 en GB ...
Page 226: ...02 16 EN 6 ...
Page 228: ...02 16 EN 8 14 Safety instructions and warning information ...
Page 250: ......