Lead acid batteries with armour plated cells and liquid
electrolyte
4.1
Description
Jungheinrich traction batteries are lead acid batteries with armour plated cells and
liquid electrolyte. The names of the traction batteries are PzS, PzB, PzS Lib and PzM.
Electrolyte
The rated density of the electrolyte assumes a temperature of 30°C and the rated
electrolyte level is fully charged. Higher temperatures will reduce, lower
temperatures will increase the electrolyte density.
The corresponding adjustment factor is ± 0.0007 kg/l per K, e. g. electrolyte density
1.28 kg/l at 45 °C corresponds to a density of 1,29 kg/l at 30 °C.
The electrolyte must comply with the purity regulations of DIN 43530 Part 2.
Name
Explanation
PzS
– Lead acid battery with "Standard" armour plated cells and liquid
electrolyte
– Battery cell width: 198 mm
PzB
– Lead acid battery with "British Standard" armour plated cells
and liquid electrolyte
– Battery cell width: 158 mm
PzS Lib
– Lead acid battery with "Standard" armour plated cells and liquid
electrolyte
– Lead acid battery with extended maintenance interval
– Battery cell width: 198 mm
PzM
Summary of Contents for EJD 220
Page 1: ...EJD 220 01 10 Operating instructions 51132781 04 19 en GB EJD 220...
Page 2: ...2...
Page 4: ...4 04 19 en GB...
Page 10: ...10 04 19 en GB...
Page 12: ...0506 GB 2 0506 GB 2...
Page 18: ...16 04 19 en GB...
Page 26: ...4 2 Dimensions h1 h3 h4 D b1 h14 b1 b10 m2 24 04 19 en GB...
Page 59: ...53 54 57 04 19 en GB...
Page 60: ...58 04 19 en GB...
Page 120: ...Z This setting can be changed if required 118 04 19 en GB...
Page 160: ...158 04 19 en GB...
Page 180: ...111 109 110 108 178 04 19 en GB...
Page 186: ...184 04 19 en GB...
Page 198: ......
Page 202: ...02 16 EN 6...
Page 204: ...02 16 EN 8 14 Safety instructions and warning information...
Page 226: ......