02
.1
6
EN
16
4.3.3 Weekly
– After re-charging, carry out a visual inspection for dirt and physical damage.
– If the battery is charged regularly according to the IU characteristic, carry out a
compensation charge.
4.3.4 Monthly
– Towards the end of the charging process measure and record the voltages of all
the cells with the charger switched on.
– After charging measure and record the electrolyte density and the electrolyte
temperature in all the cells.
– Compare the results with the previous ones.
Z
If you find significant differences compared with the previous measurements or
differences between the cells, contact the manufacturer's customer service
department.
4.3.5 Annually
– Measure the insulation resistance of the truck in accordance with EN 1175-1.
– Measure the insulation resistance of the battery in accordance with DIN EN 1987-1.
Z
In accordance with DIN EN 50272-3 the battery insulation resistance should not be
less than 50 Ω per volt of rated voltage.
Summary of Contents for EJD 220
Page 1: ...EJD 220 01 10 Operating instructions 51132781 04 19 en GB EJD 220...
Page 2: ...2...
Page 4: ...4 04 19 en GB...
Page 10: ...10 04 19 en GB...
Page 12: ...0506 GB 2 0506 GB 2...
Page 18: ...16 04 19 en GB...
Page 26: ...4 2 Dimensions h1 h3 h4 D b1 h14 b1 b10 m2 24 04 19 en GB...
Page 59: ...53 54 57 04 19 en GB...
Page 60: ...58 04 19 en GB...
Page 120: ...Z This setting can be changed if required 118 04 19 en GB...
Page 160: ...158 04 19 en GB...
Page 180: ...111 109 110 108 178 04 19 en GB...
Page 186: ...184 04 19 en GB...
Page 198: ......
Page 202: ...02 16 EN 6...
Page 204: ...02 16 EN 8 14 Safety instructions and warning information...
Page 226: ......