ACX2000 and ACX2100 Router Environmental Specifications
The router must be installed in a rack or cabinet housed in a dry, clean, well-ventilated, and
temperature-controlled environment.
Ensure that these environmental guidelines are followed:
•
The site must be as dust-free as possible, because dust can clog air intake vents and filters, reducing the
efficiency of the router cooling system.
•
Maintain ambient airflow for normal router operation. If the airflow is blocked or restricted, or if the
intake air is too warm, the router might overheat, leading to the router temperature monitor shutting
down the router to protect the hardware components.
NOTE:
Depending on the ambient temperature, it may take up to 5 minutes for the router to
heat up to the operating temperature.
provides the required environmental conditions for normal router operation.
Table 25: Router Environmental Specifications
Value
Description
No performance degradation to 10,000 ft (3048 m)
Altitude
Normal operation ensured in relative humidity range of 5% to
90%, noncondensing
Relative humidity
•
Harsh environment: –40°F (–40°C) to 149°F (65°C)
•
Central office environment: 23°F (–5°C) to 131°F (55°C)
Temperature
•
Harsh environment: –40°F (–40°C) to 122°F (50°C)
•
Central office environment: –40°F (–40°C) to 104°F (40°C)
Commercial grade
SFP/SFP+ temperature
Designed to meet Telcordia Technologies Zone 4 earthquake
requirements
Seismic
73
Summary of Contents for ACX2000
Page 1: ...ACX2000 and ACX2100 Universal Metro Router Hardware Guide Published 2020 09 07 ...
Page 91: ...Front Panel of an ACX2000 Router 47 LEDs on ACX2000 and ACX2100 Routers 57 91 ...
Page 116: ...4 CHAPTER Maintaining Components Maintaining ACX2000 and ACX2100 Components 117 ...
Page 125: ...5 CHAPTER Troubleshooting Hardware Troubleshooting ACX2000 and ACX2100 126 ...
Page 139: ...139 ...
Page 144: ...Restricted Access Warning 144 ...
Page 148: ...148 ...
Page 161: ...Jewelry Removal Warning 161 ...
Page 164: ...Operating Temperature Warning 164 ...
Page 174: ...DC Power Disconnection Warning 174 ...
Page 178: ...DC Power Wiring Sequence Warning 178 ...