ACX5000 Router Environmental Specifications
The router must be installed in a rack or cabinet. It must be housed in a dry, clean, well-ventilated, and
temperature-controlled environment.
Follow these environmental guidelines:
•
The site must be as dust-free as possible, because dust can clog air intake vents and filters, reducing the
efficiency of the router cooling system.
•
Maintain ambient airflow for normal router operation. If the airflow is blocked or restricted, or if the
intake air is too warm, the router might overheat, leading to the router temperature monitor shutting
down the device to protect the hardware components.
provides the required environmental conditions for normal router operation.
Table 26: ACX5000 Router Environmental Tolerances
Tolerance
Description
No performance degradation to 6,562 feet (2000 meters)
Altitude
Normal operation ensured in relative humidity range of 5% through 90%,
noncondensing
•
Short-term operation ensured in relative humidity range of 5% through
93%, noncondensing
NOTE:
As defined in NEBS GR-63-CORE, Issue 3, short-term events can
be up to 96 hours in duration but not more than 15 days per year.
Relative humidity
•
Normal operation ensured in temperature range of 32° F through 104° F
(0° C through 40° C)
•
Non-operating storage temperature in shipping container: –40° F through
158° F (–40° C through 70° C)
Temperature
Designed to comply with Zone 4 earthquake requirements per NEBS
GR-63-CORE, Issue 3.
Seismic
NOTE:
Install ACX Series devices only in restricted areas, such as dedicated equipment rooms
and equipment closets, in accordance with Articles 110-16, 110-17, and 110-18 of the National
Electrical Code, ANSI/NFPA 70.
83
Summary of Contents for ACX5048
Page 1: ...ACX5048 and ACX5096 Universal Metro Router Hardware Guide Published 2020 12 14 ...
Page 99: ...NOTE USB flash drives used with the ACX5000 router must support USB 2 0 or later 99 ...
Page 145: ...5 CHAPTER Troubleshooting Hardware Troubleshooting ACX5048 and ACX5096 146 ...
Page 160: ...160 ...
Page 167: ...Restricted Access Warning 167 ...
Page 171: ...171 ...
Page 183: ...Unterminated Fiber Optic Cable Warning 183 ...
Page 188: ...Jewelry Removal Warning 188 ...
Page 191: ...Operating Temperature Warning 191 ...
Page 202: ...DC Power Disconnection Warning 202 ...
Page 206: ...DC Power Wiring Sequence Warning 206 ...