NOTE:
If the AC OK LED and the DC OK LED are unlit, either the AC power cord is not installed
properly or the power supply fuse has failed. If the AC OK LED is lit and the DC OK LED is unlit,
the AC power supply is installed properly, but the power supply has an internal failure.
SEE ALSO
Connecting AC Power to an ACX5000 Router | 112
DC Power Supply for an ACX5000 Router
The power supplies in ACX5000 routers (see
) are hot-removable and hot-insertable
field-replaceable units (FRUs) that you can install in 1 U DC ACX5048 SKUs of ACX5000 routers without
powering off the router or disrupting the routing function.
The DC power supply in 1 U ACX5048 is 650 W with dual feeds for power resiliency. The DC power
supply in the 2 U ACX5096 is 850 W with dual feeds for power resiliency. Both power supplies have a
similar design and look identical. Be sure to use the correct power supply for your chassis product SKU
(see
). See
for an example of the 1 U design and
for an example of the 2 U power supply.
Figure 22: DC Power Supply in ACX5048 Routers
3
—
1
—
Ejector lever
Terminal block
4
—
2
—
Handle
ESD grounding point
69
Summary of Contents for ACX5048
Page 1: ...ACX5048 and ACX5096 Universal Metro Router Hardware Guide Published 2020 12 14 ...
Page 99: ...NOTE USB flash drives used with the ACX5000 router must support USB 2 0 or later 99 ...
Page 145: ...5 CHAPTER Troubleshooting Hardware Troubleshooting ACX5048 and ACX5096 146 ...
Page 160: ...160 ...
Page 167: ...Restricted Access Warning 167 ...
Page 171: ...171 ...
Page 183: ...Unterminated Fiber Optic Cable Warning 183 ...
Page 188: ...Jewelry Removal Warning 188 ...
Page 191: ...Operating Temperature Warning 191 ...
Page 202: ...DC Power Disconnection Warning 202 ...
Page 206: ...DC Power Wiring Sequence Warning 206 ...