When a VPI/VCI range that you enter is a subset of an already defined range,
the specified range is not saved and an appropriate message is displayed on the
CLI interface.
■
When a VPI/VCI range that you enter encompasses one or more of the previously
defined ranges, the configuration attempt fails and an appropriate message is
displayed on the CLI interface.
Guidelines for Configuring Cell Concatenation and Cell Packing Timer for an ATM Port
Observe the following guidelines when you configure the maximum number of ATM
cells that the router can concatenate in a single packet and the identifier of the ATM
Martini cell packing timer that you want to use to detect timeout of the cell collection
threshold:
■
You can configure the
mpls-relay atm cell-packing mcpt-timer
command on
the ATM port only after you associated a pseudowire with the port by using the
mpls-relay
or
route interface tunnel
command.
■
You can use this command only on an ATM port (ATM AAL5 over ATM major
interface). When you attempt to run this command on other interface types,
such as ATM subinterfaces or Ethernet interfaces, this setting is not saved and
an error message is displayed.
Performance Impact and Scalability Considerations
Because the support for multiple ATM VCs over a single pseudowire requires one
pseudowire per ATM port and the number of ATM ports in a fully populated ERX
chassis is in the order of a few tens of ports, the number of pseudowires required is
also of the same range. As a result, no performance impact is caused by LDP signaling
and state management. The amount of memory needed and initial CPU activity on
the line module for a specified range are proportional to the number of VCs in the
range.
You can scale the number of virtual circuits configured on an ATM line module up
to 16,000. The VPI/VCI range specification on the ATM ports for this feature is
controlled by this limit. Depending on other VPI/VCI configuration on the ATM line
module, the range specification must not be greater than this scaled limit subtracted
from the other VPI/VCI configuration.
A VPI/VCI range with the maximum number of VCs does not cause the line module
to become unstable. Support for unified ISSU and high availability with a VPI/VCI
range configured with the maximum number of VCs is provided.
Related Topics
■
Multiple ATM Virtual Circuits over a Single Pseudowire Example on page 560
■
mpls-relay atm vpi-range vci-range
■
mpls-relay atm cell-packing mcpt-timer
528
■
Multiple ATM Virtual Circuits over a Single Pseudowire Overview
JUNOSe 11.1.x BGP and MPLS Configuration Guide
Summary of Contents for BGP
Page 6: ...vi ...
Page 8: ...viii JUNOSe 11 1 x BGP and MPLS Configuration Guide ...
Page 37: ...Part 1 Border Gateway Protocol Configuring BGP Routing on page 3 Border Gateway Protocol 1 ...
Page 38: ...2 Border Gateway Protocol JUNOSe 11 1 x BGP and MPLS Configuration Guide ...
Page 234: ...198 Monitoring BGP JUNOSe 11 1 x BGP and MPLS Configuration Guide ...
Page 236: ...200 Multiprotocol Layer Switching JUNOSe 11 1 x BGP and MPLS Configuration Guide ...
Page 542: ...506 Monitoring BGP MPLS VPNs JUNOSe 11 1 x BGP and MPLS Configuration Guide ...
Page 544: ...508 Layer 2 Services Over MPLS JUNOSe 11 1 x BGP and MPLS Configuration Guide ...
Page 610: ...574 Virtual Private LAN Service JUNOSe 11 1 x BGP and MPLS Configuration Guide ...
Page 624: ...588 VPLS References JUNOSe 11 1 x BGP and MPLS Configuration Guide ...
Page 680: ...644 Virtual Private Wire Service JUNOSe 11 1 x BGP and MPLS Configuration Guide ...
Page 724: ...688 Monitoring MPLS Forwarding Table for VPWS JUNOSe 11 1 x BGP and MPLS Configuration Guide ...
Page 725: ...Part 6 Index Index on page 691 Index 689 ...
Page 726: ...690 Index JUNOSe 11 1 x BGP and MPLS Configuration Guide ...