Replacing Alarm Relay Wires
67
CHAPTER 10: Replacing Hardware Components
6.
Remove the rubber safety cap from the SFP and the end of the cable. Insert the cable into the
SFP.
7.
Verify that the status LEDs above the SFP slot indicate that the fiber-optic port is functioning
normally. For more information on LEDs on the fiber-optic port, see “Ethernet Ports” on
8.
After replacing the SFPs and connecting the cables, issue the following command to ensure
that the interface is operational:
cli@BX7000>
show interface
interface-name
Figure 29: Installing an SFP
Replacing Alarm Relay Wires
To replace the wires connected to an external alarm device (see Figure 30 on page 67):
1.
Disconnect the existing wire at the external device.
2.
Prepare the required length of replacement wire.
3.
Using a screwdriver, push the body cover of the connector located on the top of the wire which
is to be disconnected from the wire-trap connector.
4.
Remove the wire from the ALARM slot and release the body cover of the connector.
5.
Push the replacement wire into the ALARM slot.
6.
Connect the other end of the wire to the external device.
Figure 30: Alarm Relay
FLASH
CONSOLE
COPPER
COPPER
COPPER
SFP
SFP
ALARM
ETHERNET 1
ETHERNET 1
ETHERNET 2
ETHERNET 2
ETHERNET 0
CONSOLE
g002913
Summary of Contents for BX7000
Page 10: ... x Copyright 2010 Juniper Networks Inc ...
Page 12: ... xii Copyright 2010 Juniper Networks Inc ...
Page 18: ...About This Guide xviii Requesting Support Copyright 2010 Juniper Networks Inc ...
Page 20: ... 2 Copyright 2010 Juniper Networks Inc ...
Page 66: ... 48 Copyright 2010 Juniper Networks Inc ...
Page 90: ... 72 Copyright 2010 Juniper Networks Inc ...
Page 122: ... 104 Hardware Compliance Copyright 2010 Juniper Networks Inc ...
Page 131: ...Copyright 2010 Juniper Networks Inc 113 Appendix E Declaration of Conformity ...
Page 132: ... 114 Copyright 2010 Juniper Networks Inc ...
Page 133: ...Copyright 2011 Juniper Networks Inc 115 PART 4 Index z Index on page 117 ...