Fast Ethernet Cables
The Ethernet connection is a standard RJ-45 connector. Typically, a straight-through cable is used to
connect to a switch, and a crossover cable is used to connect to a router.
DC Power Cables
For CTP chassis with DC power options, we recommend 18-AWG power cables.
RELATED DOCUMENTATION
Required Tools, Wires, and Cables for the CTP2000 Platform | 109
Cabling the CTP Platform for DC Power | 111
Terminal Block and Circuit Breaker Specifications | 69
Terminal Block and Circuit Breaker Specifications
lists the electrical specifications for the terminal block (see
)
located on the back of the CTP2000 Series DC chassis.
Table 23: Terminal Block Electrical Specifications
Specification
Category
100 VDC
Voltage
20 A
Current
−55° through 105° C
Operating Temperature
Black thermoplastic or equivalent
Material
Minimum: 2500 pF
Maximum: 5200 pF
Capacitance
69