Installing the CTP2000 Platform in Freestanding Mode
When installing the device on a table top or in any other freestanding mode, be sure to leave enough space
around the device for adequate ventilation. Position the chassis with easy access to the connections that
it needs for power, local communications, and remote communications.
WARNING:
At least two people are required to lift the device. Three people are
required for the heavier CTP platforms.
CAUTION:
To prevent electrostatic damage to the device and its components, make
sure that persons handling the device wear an antistatic device.
RELATED DOCUMENTATION
Before You Install the CTP2000 Platform | 90
Installing the CTP2000 Platform in a Rack | 92
Cabling the CTP2000 Platform Overview | 108
Special Guidelines for Installing CTP2056 Chassis in a Rack
Before installing the CTP2056 platform in a rack, consider the following guidelines:
•
You can install up to four CTP2056 chassis in a single 7-ft. (2.1-m) rack. Installing multiple devices in a
single rack enables you to maximize your available space.
•
Install the CTP2056 chassis on the bottom of the rack. Mount lighter devices higher in the rack.
RELATED DOCUMENTATION
CTP2000 Rack Requirements | 42
Installing the CTP2000 Platform in a Rack | 92
91
Summary of Contents for CTP2000 Series
Page 1: ...CTP2000 Series Circuit to Packet Platforms Hardware Guide Published 2020 08 31 ...
Page 8: ...1 PART Overview CTP2000 Series Platform Overview 2 CTP2000 Series Interface Modules 11 ...
Page 112: ...Installing SFPs in a CTP2000 Module 102 105 ...
Page 127: ...5 PART Configuration Accessing the CTP2000 Platform 121 ...
Page 144: ...7 PART Troubleshooting Troubleshooting Power Failures 138 Contacting Customer Support 140 ...