Figure 1: Flip the Enable Switch to the ON position
8.
Repeat Step 7 for the remaining power supplies installed in the switch.
9.
On the external management device, monitor the startup process to ensure that
the system boots properly.
NOTE:
After you power on a power supply, wait for at least 60 seconds before you
turn it off. After you power off a power supply, wait for at least 60 seconds before
you turn it back on.
If the system is completely powered off when you switch on a power supply, the
SRE or RE module boots as the power supply completes its startup sequence.
After you power on a power supply, it can take up to 60 seconds for status indicators
such as power supply LEDs and the
show chassis
operational mode CLI command
display to indicate that the power supply is functioning normally. Ignore any error
indicators that might appear during the first 60 seconds.
Related Topics
■
Installing an AC Power Supply in an EX 8200 series Switch
■
Installing a DC Power Supply in an EX 8200 series Switch
■
Connecting AC Power to an EX 8200 series Switch
■
Connecting DC Power to an EX 8200 series Switch
■
Powering Off an EX 8200 series Switch
2
■
Powering On an EX 8200 series Switch