• ESD grounding strap.
• Power cord or cords appropriate for your geographical location.
CAUTION: Before you connect power to the JATP400 appliance, ensure both power
supply ground terminals are grounded to meet the safety requirements and to ensure
proper operation.
To connect AC power to a JATP400 appliance:
1. To prevent damage to the equipment caused by static discharge, attach one end of an ESD strap to
an ESD point and fasten the other end around your bare wrist.
2. Ensure that the power supplies are fully inserted in the chassis and the latches are secure.
3. Locate the power cord or cords shipped with the JATP400 appliance.
4. Plug the power cord into the AC receptacle on the rear panel as shown in
.
If your appliance contains two power supplies, plug each of the power cords into each of the AC
receptacles.
Figure 13: Connecting the AC Power Cord
NOTE: Grounding for the appliances is provided through the power supply ground terminal.
Ensure that you connect the AC power supply module in the appliance to a grounded AC
power outlet by using an AC power cord (with the grounding pin) appropriate for your
geographical location.
5. Plug the other end of the power cord into a wall socket.
6. Press the Power button on the front panel.
7. Verify that the status LEDs of the power supply is lit solid green.
36
Summary of Contents for JATP400
Page 1: ...JATP400 Appliance Hardware Guide Published 2021 05 17...
Page 8: ...1 CHAPTER Overview JATP400 System Overview 2 JATP400 Chassis 4...
Page 64: ...The hard drive pops partially out of the slot 57...
Page 65: ...Figure 24 Removing a Drive Carrier g100245 58...
Page 67: ...5 CHAPTER Troubleshooting Hardware Contacting Juniper Networks Technical Assistance Center 61...
Page 69: ...6 CHAPTER Returning the Chassis or Components Returning the JATP400 Chassis or Components 63...
Page 72: ...Maintaining the JATP400 Hard Disk Drive 56 65...