Basic Configuration of a Virtual Chassis with Master and Backup Switches
To take advantage of the Virtual Chassis configuration’s higher bandwidth capacity and
software redundancy features, you need to interconnect at least two EX4200 switches
in a Virtual Chassis configuration. You can start with a default configuration, composed
of two EX4200
member switches
interconnected through the dedicated 64-Gbps
Virtual
Chassis ports (VCPs)
on their rear panels. These ports do not have to be configured. They
are operational as soon as the member switches are powered on. See “Example:
Configuring a Virtual Chassis with a Master and Backup in a Single Wiring Closet” on
page 947 for additional information.
Expanding Configurations—Within a Single Wiring Closet and Across Wiring Closets
As your needs grow, you can easily expand the Virtual Chassis configuration to include
more member switches. Within a single wiring closet, simply add member switches by
cabling together the dedicated VCPs. For more information about expanding Virtual
Chassis configurations within a single wiring closet, see “Example: Expanding a Virtual
Chassis Configuration in a Single Wiring Closet” on page 952 and “Example: Setting Up a
Multimember Virtual Chassis Access Switch with a Default Configuration” on page 957.
You can also expand a Virtual Chassis configuration beyond a single wiring closet.
Interconnect switches located in multiple wiring closets or in multiple data center racks
by installing the optional SFP, SFP+, or XFP uplink modules and connecting the uplink
module ports or by connecting the 1-gigabit network interfaces in an EX4200-24F switch.
The small form-factor pluggable (SFP) uplink module provides four ports for 1-gigabit
transceivers. The SFP+ uplink module provides two ports for 10-gigabit SFP+ transceivers
or four ports for 1-gigabit SFP transceivers. The XFP uplink module provides two ports
for 10-gigabit XFP transceivers. To use SFP, SFP+, and XFP uplink module ports or
EX4200-24F network interfaces for interconnecting member switches, you must first
explicitly configure them as
Virtual Chassis ports (VCPs)
. This procedure includes
configuring these ports of a standalone EX4200 switch as VCPs prior to interconnecting
the new member switch with the existing Virtual Chassis configuration. See “Example:
Configuring a Virtual Chassis Interconnected Across Multiple Wiring Closets” on page 963
for detailed information.
When you are creating a Virtual Chassis configuration with multiple members, you might
want to deterministically control the role and member ID assigned to each member
switch. You can do this by creating a preprovisioned configuration. See “Example:
Configuring a Virtual Chassis Using a Preprovisioned Configuration File” on page 982 for
more information.
You can add switches to a preprovisioned configuration by using the autoprovisioning
feature to automatically configure the uplink module ports as VCPs on the switches
being added. See “Adding a New Switch to an Existing Virtual Chassis Configuration (CLI
Procedure)” on page 1016 for detailed information.
Copyright © 2010, Juniper Networks, Inc.
922
Complete Software Guide for Junos
®
OS for EX Series Ethernet Switches, Release 10.3
Summary of Contents for JUNOS OS 10.3 - SOFTWARE
Page 325: ...CHAPTER 17 Operational Mode Commands for System Setup 229 Copyright 2010 Juniper Networks Inc ...
Page 1323: ...CHAPTER 56 Operational Mode Commands for Interfaces 1227 Copyright 2010 Juniper Networks Inc ...
Page 2841: ...CHAPTER 86 Operational Commands for 802 1X 2745 Copyright 2010 Juniper Networks Inc ...
Page 3367: ...CHAPTER 113 Operational Mode Commands for CoS 3271 Copyright 2010 Juniper Networks Inc ...
Page 3435: ...CHAPTER 120 Operational Mode Commands for PoE 3339 Copyright 2010 Juniper Networks Inc ...
Page 3529: ...CHAPTER 126 Operational Mode Commands for MPLS 3433 Copyright 2010 Juniper Networks Inc ...