Virtual Chassis ID: 0019.e250.47a0
Mastership Neighbor List
Member ID Status Serial No Model priority Role ID Interface
0 (FPC 0) Prsnt AK0207360276 ex4200-48p 128 Master* 1 vcp-0
1 vcp-1
1 (FPC 1) Prsnt AK0207360281 ex4200-24t 128 Backup 0 vcp-0
0 vcp-1
Member ID for next new member: 2 (FPC 2)
Meaning
The show virtual-chassis status command lists the member switches interconnected in
a Virtual Chassis configuration with the member IDs that have been assigned by the
master, the mastership priority values, and the roles. It also displays the neighbor members
with which each member is interconnected. The output shows that SWA-0, member 0,
has been assigned default mastership priority 128. Because SWA-0 is the first member
to be powered on, it has the most seniority and is therefore assigned the role of master.
SWA-1 is powered on after member 0, so it is assigned the role of backup. The member
IDs are displayed on the front panel of the switches. Check and confirm whether the
default assignment is satisfactory.
Verifying That the VCPs Are Operational
Purpose
Verify that the dedicated Virtual Chassis ports interconnecting the switches are
operational.
Action
Display the Virtual Chassis ports of all the members:
user@SWA-0>
show virtual-chassis vc-port
all-members
fpc0:
--------------------------------------------------------------------------
Interface Type Status Speed Neighbor
or (mbps) ID Interface
PIC / Port
vcp-0 Dedicated Up 32000 1 vcp-1
vcp-1 Dedicated Up 32000 1 vcp-0
fpc1:
--------------------------------------------------------------------------
Interface Type Status Speed Neighbor
or (mbps) ID Interface
PIC / Port
vcp-0 Dedicated Up 32000 1 vcp-0
vcp-1 Dedicated Up 32000 1 vcp-1
Meaning
The show virtual-chassis vc-port command lists the interfaces that are enabled for the
member switches of the Virtual Chassis configuration and shows the status of the
interfaces. The output in this example shows that two of the VCPs are operational and
two VCPs are not. A single cable has been used to interconnect vcp-0 of member ID 0
and vcp-0 of member ID 1. That interconnection is sufficient for the switch to be
operational. However, we recommend that you connect the second set of VCPs for
redundancy.
951
Copyright © 2010, Juniper Networks, Inc.
Chapter 44: Virtual Chassis—Configuration Examples
Summary of Contents for JUNOS OS 10.3 - SOFTWARE
Page 325: ...CHAPTER 17 Operational Mode Commands for System Setup 229 Copyright 2010 Juniper Networks Inc ...
Page 1323: ...CHAPTER 56 Operational Mode Commands for Interfaces 1227 Copyright 2010 Juniper Networks Inc ...
Page 2841: ...CHAPTER 86 Operational Commands for 802 1X 2745 Copyright 2010 Juniper Networks Inc ...
Page 3367: ...CHAPTER 113 Operational Mode Commands for CoS 3271 Copyright 2010 Juniper Networks Inc ...
Page 3435: ...CHAPTER 120 Operational Mode Commands for PoE 3339 Copyright 2010 Juniper Networks Inc ...
Page 3529: ...CHAPTER 126 Operational Mode Commands for MPLS 3433 Copyright 2010 Juniper Networks Inc ...