Table 158: show virtual-chassis vc-port Output Fields
(continued)
Field Description
Field Name
Type of VCP:
•
Dedicated
(on the rear panel)
•
Configured
(uplink module port configured as a VCP)
•
Auto-Configured
(uplink module port autoconfigured as a VCP)
See “Setting an Uplink Module Port as a Virtual Chassis Port (CLI Procedure)” on page 1023 for
information about configuring VCPs.
Type
A positive-number ID assigned to a LAG formed by the Virtual Chassis. The trunk ID value is
–1
if no
trunk is formed. A LAG between uplink VCPs requires that the link speed be the same on connected
interfaces and that at least two VCPs on one member be connected to at least two VCPs on the other
member.
Dedicated VCP LAGs are assigned trunk IDs 1 and 2. Trunk IDs for LAGs formed with uplink VCPs
therefore have values of 3 or greater.
The trunk ID value changes if the link-adjacency state between LAG members changes; trunk
membership is then allocated or deallocated.
Trunk ID
Interface status:
down
or
up
.
Status
Speed of the interface in megabits per second.
Speed (mbps)
The Virtual Chassis member ID and interface of a VCP on a member switch that is connected to the
interface or PIC/Port field in the same row as this interface.
Neighbor
ID/Interface
show virtual-chassis
vc-port
user@switch>
show virtual-chassis vc-port
fpc0:
show virtual-chassis
vc-port
-------------------------------------------------------------------------–
Interface Type Trunk Status Speed Neighbor
or ID (mbps) ID Interface
PIC / Port
vcp-0 Dedicated 1 Up 32000 1 vcp-1
vcp-1 Dedicated 2 Up 32000 0 vcp-0
1/0 Auto-Configured 3 Up 1000 2 vcp-255/1/0
1/0 Auto-Configured 3 Up 1000 2 vcp-255/1/1
show virtual-chassis
vc-port all-members
user@switch>
show virtual-chassis vc-port all-members
fpc0:
--------------------------------------------------------------------------
Interface Type Trunk Status Speed Neighbor
or ID (mbps) ID Interface
PIC / Port
vcp-0 Dedicated 1 Up 32000 1 vcp-1
vcp-1 Dedicated 2 Up 32000 0 vcp-0
1/0 Auto-Configured 3 Up 1000 2 vcp-255/1/0
1/1 Auto-Configured 3 Up 1000 2 vcp-255/1/1
fpc1:
Copyright © 2010, Juniper Networks, Inc.
1084
Complete Software Guide for Junos
®
OS for EX Series Ethernet Switches, Release 10.3
Summary of Contents for JUNOS OS 10.3 - SOFTWARE
Page 325: ...CHAPTER 17 Operational Mode Commands for System Setup 229 Copyright 2010 Juniper Networks Inc ...
Page 1323: ...CHAPTER 56 Operational Mode Commands for Interfaces 1227 Copyright 2010 Juniper Networks Inc ...
Page 2841: ...CHAPTER 86 Operational Commands for 802 1X 2745 Copyright 2010 Juniper Networks Inc ...
Page 3367: ...CHAPTER 113 Operational Mode Commands for CoS 3271 Copyright 2010 Juniper Networks Inc ...
Page 3435: ...CHAPTER 120 Operational Mode Commands for PoE 3339 Copyright 2010 Juniper Networks Inc ...
Page 3529: ...CHAPTER 126 Operational Mode Commands for MPLS 3433 Copyright 2010 Juniper Networks Inc ...