continuity-check (EX Series Switch Only)
Syntax
continuity-check {
hold-interval
minutes;
interval
(10m | 10s | 1m | 1s| 100ms);
loss-threshold
number;
}
Hierarchy Level
[edit protocols
oam ethernet connectivity-fault-management maintenance-domain
domain-name
maintenance-association
ma-name]
Release Information
Statement introduced in Junos OS Release 10.2 for EX Series switches.
Description
Specify continuity check protocol options.
The remaining statements are explained separately.
Required Privilege
Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Related
Documentation
•
Configuring Ethernet OAM Connectivity Fault Management (CLI Procedure) on page 3768
•
Junos OS Network Interfaces Configuration Guide
at
http://www.juniper.net/techpubs/software/junos/index.html
direction (EX Series Switch Only)
Syntax
direction down;
Hierarchy Level
[edit protocols
oam ethernet connectivity-fault-management maintenance-domain
domain-name
maintenance-association
ma-name
mep
mep-id]
Release Information
Statement introduced in Junos OS Release 10.2 for EX Series switches.
Description
Specify that connectivity fault management (CFM) packets (CCMs) be transmitted only
in one direction for the MEP, that is, the direction be set as
down
so that CCMs are
transmitted only out of (not into) the interface configured on this MEP.
Options
down
—Down MEP CCMs are transmitted only out (not into) of the interface configured
on this MEP.
Required Privilege
Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Related
Documentation
•
Configuring Ethernet OAM Connectivity Fault Management (CLI Procedure) on page 3768
•
Junos OS Network Interfaces Configuration Guide
at
http://www.juniper.net/techpubs/software/junos/index.html
3783
Copyright © 2010, Juniper Networks, Inc.
Chapter 132: Ethernet OAM Connectivity Fault Management
Summary of Contents for JUNOS OS 10.3 - SOFTWARE
Page 325: ...CHAPTER 17 Operational Mode Commands for System Setup 229 Copyright 2010 Juniper Networks Inc ...
Page 1323: ...CHAPTER 56 Operational Mode Commands for Interfaces 1227 Copyright 2010 Juniper Networks Inc ...
Page 2841: ...CHAPTER 86 Operational Commands for 802 1X 2745 Copyright 2010 Juniper Networks Inc ...
Page 3367: ...CHAPTER 113 Operational Mode Commands for CoS 3271 Copyright 2010 Juniper Networks Inc ...
Page 3435: ...CHAPTER 120 Operational Mode Commands for PoE 3339 Copyright 2010 Juniper Networks Inc ...
Page 3529: ...CHAPTER 126 Operational Mode Commands for MPLS 3433 Copyright 2010 Juniper Networks Inc ...